background image

3

Modules & Connecting Blocks

789-44

Fig. 3

  Using the STATUS terminal in a typical system (see text, pg 4).

6-15-00

Using The "STATUS" Terminal on the 789-44

Fig. 3 illustrates a single zone system where the Status LED on a Xantech 780-80 IR Receiver, in the remote
room, shows the ON/OFF status of an A/V receiver.

• The STATUS and GND terminals on the 789-44 provide  convenient tie points for the voltage that drives

STATUS indicators on certain Xantech products (such as the 780-80 IR Receiver).

To connect such a system, proceed as follows:

1. Be sure all power plugs for the A/V system are un-plugged before proceeding with the following

connections.

2. Plug a 12V adapter, such as the Xantech 786-00 Power Supply, into the switched

 AC Outlet on the

back of  the A/V receiver (or integrated amplifier, preamp, etc.).

3. The 12V leads of the adapter (cut attached plug off) are then connected between the STATUS and

GND terminals on the 789-44 ("+" to STATUS, "" to GND).

4. You would then connect the 4-conductor inter-room cable between the 789-44 and the 780-80 as

shown in Fig. 3.

5. If you wish to adjust the brightness of the Status LED, place  a resistor in series with the STATUS lead

as shown in Fig. 3.  Use a value that achieves the desired brightness level (usually 1k Ohm to 10k Ohm,
1/8 watt).

CAUTION NOTE

When using long lengths (>50 ft.) of inter-room
shielded cable, it may be necessary to connect a
470 Ohm 1/8 Watt resistor between IR IN and
GND at the connector terminals of the 789-44.
Refer to Fig.4.

The resistor discharges the cable capacitance
more quickly, allowing IR codes of high bit rates
to pass without data loss.

MOUNTING

The 789-44 can be conveniently mounted to a wall or shelf by using the two sheet-metal screws supplied.
The unit may be mounted in any orientation to accommodate the installation.

+ 1 2   V D C

G N D

S TAT U S

I R   I N

470 Ohm
resistor

Shielded Cable
to remote room

789-44 Input
Terminals

Ground Shield as shown

Fig. 4

  470 Ohm Capacitance Discharge Resistor

+12VDC

STATUS

GND

IR OUT

780-80

IR RECEIVER

XANTECH CORP

.

SYLMAR, CA

  91342

283M

 

Blink-IR™

Mouse Emitter

To 120 V AC

(unswitched)

781RG

Power Supply

789-44

Connecting Block

283M

 Blink IR™

282M

 Emitter

Hand Held

Remote

VCR

GND

IR OUT

+12V

780-80

J-Box

IR Receiver

(rear view)

4-Conductor
Inter-room Cable
(unshielded OK)

STATUS

White Striped Side ("+")

786-00

Power Supply

(12V at 10 mA)

Plug into

Switched AC Outlet

on A/V Receiver

(see text)

Add resistor in series

with STATUS line to

adjust brightness, if desired.

(See text, next page).

REMOTE ROOM

MAIN ROOM

+

12VDC

+12 VDC

GND

STATUS

IR IN

EMITTERS

IR

RCVR

789-44

CONNECTING BLOCK

®

A/V Receiver

Satellite Receiver

Reviews: