background image

3

Modules & Connecting Blocks

789-44D

+12V

STATUS

GND

OUTPUT

780-80

IR RECEIVER

XANTECH CORP

.

SYLMAR, CA

  91342

MADE IN U.S.A.

283M

 

Blink-IR™

Mouse Emitter

To 120 V AC
(Unswitched)

781C-00

Power Supply

789-44D

Connecting

Block

283M

 Blink IR™

282M

 Emitter

Hand Held

Remote

VCR

GND

OUT

+12V

780-80

J-Box

IR Receiver

(rear view)

4-Conductor
Inter-room Cable
(unshielded OK)

STATUS

White Striped
Side ("+")

781C-00

Power

Supply

(12V at
10 mA)

Plug into

Switched AC

Outlet on A/V

Receiver

(see text)

Add resistor in series

with STATUS line to

adjust brightness, if desired.

(See text, next page).

REMOTE ROOM

MAIN ROOM

+

A/V Receiver

Satellite Receiver

+12V

GND

IR IN

STATUS

6. The emitter ports are driven in parallel with a 470-Ohm  resistor connected in series with each port.

The resistors ensure proper current sharing to each emitter.  When using less than 4 emitters, you may
plug them into any of the 4 emitter ports without regard to order.

7. Because of this current sharing feature, you may plug in any combination of the Xantech 282, 283, 284

& 286 series emitters (up to a maximum of 8 individual emitters) to drive the desired number of devices.

NOTE 1:  Be sure the Power Supply is plugged into an un-switched AC outlet.  This maintains the
system in "standby" operation so that power-on commands can be sent to the controlled equipment.

Fig. 3

  Using the STATUS terminal  in a typical system

Using The "STATUS" Terminal on the 789-44D

Fig. 3 illustrates a single zone system where the Status LED on a Xantech 780-80 IR Receiver, in the remote
room, shows the ON/OFF status of an A/V receiver.

• The STATUS and GND terminals on the 789-44D provide  convenient tie points for the voltage that drives

STATUS indicators on certain Xantech products (such as the 780-80 IR Receiver).

To connect such a system, proceed as follows:

1. Be sure all power plugs for the A/V system are unplugged before proceeding with the following

connections.

2. Plug a 12V adapter, such as the Xantech 781C-00 Power Supply, into the 

switched AC Outlet on the

back of  the A/V receiver (or integrated amplifier, preamp, etc.).

3. The 12V leads of the adapter (cut attached plug off) are then connected between the STATUS and

GND terminals on the 789-44D ("+" to STATUS, "" to GND).

4. You would then connect the 4-conductor inter-room cable between the 789-44D and the 780-80 as

shown in Fig. 3.

5. If you wish to adjust the brightness of the Status LED, place a resistor in series with the STATUS lead

as shown in Fig. 3.  Use a value that achieves the desired brightness (usually 1k Ohm to 10k Ohm,
1/8 watt).