1
Accessories
INSTALLATION INSTRUCTIONS
BYPASS94
IR BYPASS KIT
The BYPASS94 routes Infrared control signals around RF amplifiers and non-DC passing splitters.
10-19-99
Short Coaxial Jumper Cables
CPL10
Couplers
3.5/3.5mm Mono Mini Plug Cable
IR
RF
RF/IR
CPL10 COUPLER
IR
RF
RF/IR
CPL10 COUPLER
CPL10 COUPLER
I R
RF
RF/IR
IN
OUT
CPL10
3.5/3.5mm Mono
Mini Plug Cable
Coaxial cable
to IR receivers
and TVs
RF Amp
CPL10
Short Coaxial
Jumper Cable
Short Coaxial
Jumper Cable
Coaxial cable
from IR controlled
RF sources
CPL10 COUPLER
I R
RF
RF/IR
BYPASS94 Kit Parts
The kit includes the following parts:
2- CPL10 RF/IR Couplers
2- Short coaxial jumper cables, with "F" connectors on each end.
1- Connector cable with 3.5mm mono mini plugs on each end.
INSTALLATION
The following diagram illustrates how to connect the kit parts into a coaxial line to route the IR control signal
around an RF amplifier in an RF system.
IMPORTANT:
Be sure that the IN and OUT terminals of the RF Amp are connected to the terminals marked
"RF" on the CPL10 Couplers.
Use the same technique to bypass non-DC passing splitters or other RF devices.