INSTALLATION INSTRUCTIONS 

 

MODEL CSM1-77 

MRC44 Current Sense Module 

(110/220VAC Edition) 

 
 

IEC power cord
from component

IEC power cord
to AC power source

Tip=+12v Input

Ring=9v DC (15mA) Output

Sleeve=GND

Insulators

3.5mm Mini Plug

(3-Conductor)

 

 

To AC

Source

From

Component

Figure 1 – CSM1-77 

MRC44 Current Sense Module 

Figure 2 – CSM1 Connections 

 

Sense Input Connections (MRC44 Controller) 

The sense input connection will typically be used to sense the power state of a source component 
using the Xantech CSM1-77 Current Sense Module. Plug the 3.5mm miniplug from the CSM1-77 
into the appropriate sense jack on the MRC44. The CSM1 plugs into a 110/220V AC power 
source via a Female IEC adaptor. The component power cord plugs into the CSM1 via a male 
IEC adaptor (see Figures 1 & 2).  

 

CSM1-77 Threshold Adjustments 

a.  First, make sure the 3.5mm mini-plug is plugged into the appropriate sense jack on the 

MRC44 and that the MRC44 is powered ON.  (The CSM1 gets low-voltage DC power from 
the MRC44 – not from the AC line. See Figure 2-Top for mini-jack pin out ) 

b.  Select the correct position of the RANGE slider switch – the HI position is for devices with a 

high current draw when ON, the LO position is for devices with a low current draw when ON 
(based upon the lowest current draw state of the component when ON). 

c.  Manually turn the component ON. 
d.  Using a small (1/8” wide) blade screwdriver, rotate the current control to the full CLOCKWISE 

position (LO CURRENT). 

e.  Rotate the control COUNTER-CLOCKWISE (towards the HI CURRENT position) until the 

Threshold Adjustment LED goes OFF. 

f.  Turn the component OFF (standby mode). 
g.  Rotate the control CLOCKWISE until the Threshold Adjustment just goes ON. 
h.  Set the control to a point midway between these two settings.  This should be the correct 

setting. 

 
NOTE 1:

  If you have trouble with the threshold adjustment correctly detecting the ON and OFF 

states of the component, try changing the RANGE slider to the opposite position and then try the 
adjustment again. 

NOTE 2:

  If the Threshold Adjustment LED does not go ON and OFF with the component power, 

make minor adjustments to the threshold adjust until the LED is in proper sync. 

NOTE 3:

  Program IR commands for the MRC44 Controller current sensing as described in the 

MRC44 Installation Instructions, “PROGRAMMING SENSE CODES”. 

 