background image

4 of 11 

C

ONFIGURING THE 

XANTECH

 

XLIP 

The XLIP units come out of the box with a DHCP network configuration.  We recommend setting these to 
use a static IP address.   

If you have multiple XLIPs in an installation, power them up one at a time and change the IP address as 
follows. Each XLIP must be on a different IP and listening on a different UDP port. 

The default configuration web page for the Xantech devices is:   

http://xlip232r-[last 6 digits of MAC address for the device] 

 

1.  Click on the Configuration Link.  The device’s default credentials are UserID: admin, Password:  

Xantech 

2.  In Configuration, set the following options: 

a.  Function of the module should be set to “This module is stand alone” 

b.  Use DHCP for IP address should be deselected, and network information should be 

entered. 

c.  If using multiple XLIP devices, the UDP port used for IR must be unique for each device. 

In the Computer Address Section, set the Computer IP to the IP Address of your HC/SC 

Summary of Contents for ELAN Xtranet XLIP232

Page 1: ...to existing systems IR Input The Xtranet Modules are compatible with all Xantech 30 60KHz IR Receivers Most A V equipment utilizes an IR carrier frequency between 20 to 60KHz Xantech also Manufactures...

Page 2: ...CH XLIP 4 If using IR from the XANTECH XLIP install the equipment that will be controlled by the XANTECH XLIP and run IR flashers back from each piece of equipment to the XANTECH XLIP 5 If more than t...

Page 3: ...N o tes DB9M to RJ45 Adapter ELAN HA CB 307 RS 232 DB 9 M ale X RJ 45 Female Cat5 Cable Assy Installer N A RS 232 RJ 45 M ale X RJ 45 M ale M ust terminate all 8 conductors DB9F to RJ45 Adapter ELAN H...

Page 4: ...web page for the Xantech devices is http xlip232r last 6 digits of MAC address for the device 1 Click on the Configuration Link The device s default credentials are UserID admin Password Xantech 2 In...

Page 5: ...that Use all Emitter outputs is selected All other settings are generally unchanged Consult the XLIP Device s documentation for information on Code Timing Options 4 In the RS232 Setup page set the RS...

Page 6: ...6 of 11...

Page 7: ...m port is used to control a lighting system the XLIP com device is only configured on the lighting tab of the configurator The proper selection for a com device using a XLIP com port is IP to Serial X...

Page 8: ...8 of 11 As mentioned above the XLIP s Computer IP should be set to the HC SC s address and Attempt to locate PC should be selected The g driver will populate this setting on the XLIP device...

Page 9: ...9 of 11...

Page 10: ...t Default Xantech XLIP RS 232 XLIP232 Only Name User Defined Communication Type Standard Connection Hardware Type IP to Serial Xantech XLIP232 XLIP Device discovered Ip Address user defined Port User...

Page 11: ...RS 232 baud rate in the Xantech Configuration The baud rate setting in g will not have an effect on the 3 No RS 232 Communications Make sure that the g configuration is using the TCP port for RS 232...

Reviews: