ISM4 INSTALLATION & PROGRAMMING MANUAL
25
system upon detection of a change of state on any
Source Sense Input
. This feature can be enabled/disabled
via the
Enable/Disable Automatic Source Power Notification Commands
explained in the
ISM4 RS232
Command Strings Table
above.
The
Source Power Notification Data String
contains
Power Status
information for all four
Sources
. The
Notification Data Structure
is
preceded
by the ‘
#
’ character prefix and
terminated
with the ‘
+
’ character. The
Notification Data String
is parsed into four fields. Each field holds one
Source Component State Data
Structure
(one per Source Component). Each
Source Component Data Structure
holds information that
identifies the particular
source
component and its
power state
, as indicated by the definition of {0/1}, a ‘
0
’
indicates the
OFF
condition. A
‘1’
indicates an
ON
condition.
Example
#SS{S#} PR{0/1} SS{S#} PR{0/1} SS{S#} PR{0/1} SS{S#} PR{0/1}+
The
SS{S#}
field indicates which
Source
is being reported. All data that follows will pertain to
that
Source
. The
end of the current field will be flagged by the presence of another
SS{S#}
field (next Source) or the
‘+’
termination
character (end of report).
The
PR{0/1}
field indicates the
Power State
of the reported
Source
. That is, it indicates the
Power State
of the
Source
identified by the
SS{S#}
field that immediately precedes it.
The string below is an example of a string that might be sent out by the ISM4:
#SS1 PR1 SS2 PR1 SS3 PR0 SS4 PR0+
This string indicates the following:
Source 1 Power State = ON
Source 2 Power State = ON
Source 3 Power State = OFF
Source 4 Power State = OFF
The
System Info Query
can be useful in determining the build of a particular ISM4. On occasion, Xantech
Technical Personnel may ask for this information should a problematic situation occur.
ISM4 QUERIES
Name
Query
Return
Example Return
Remarks
Source Power
?{s#}PR+
?{s#}PR{0/1}+
?1PR0+{CR}
Power in Zone 1 is
OFF
System Info
?SI+
?SI
{Device:
IPM4,
Device Cde:
000F,
Hardware Cde:
0000,
Reserved Cde:
0000,
Firmware Ver:
X.Y.Z}+
?SI
Device:
IPM4, Device
Cde:
000F,
Hardware Cde:
0000,
Reserved Cde:
0000,
Firmware Ver:
1.0.0
NOTE:
This is
command does not
trickle down to the
Expansion Port.
X = Major
Y = Minor
Z = Release
NOTE:
Allowable
Syntax for the Queries includes: (Source 1 Power used for example)
?1PR+
?01PR+
RS232 Command String/Query Legend
{CR} = Carriage Return
{s#} = Source Input Number Range 1-4 or 01-04