Model MRC44KP
Page 13
© 2001 Xantech Corporation
2. Installing the Mounting Bracket
a. Attach the ground wire to the ground lug to the rear of the back-bar
with the provided green screw, before beginning the bracket
installation process.
NOTE: A ground wire connected to Earth ground is required to
protect against static discharge.
b. Run the supplied screws through the top (marked on the front of the
bracket) of the mounting bracket into the back-bar as shown in
Figure 5
.
c. Pull the CAT5 cable through the hole in the wall.
d. Pull the CAT5 cable through the hole in the mounting bracket.
e. Slide the left or right side of the back-bar into the wall.
f. Center the mounting bracket in the wall and tighten the screws until
the bracket is firmly held in the wall. Over tightening will distort the
bracket and prevent the Keypad from snapping tight against the wall.
Under tightening will cause the Keypad to be loose against the wall.
g. If there is not enough room to slide the keypad in as described
above, you can hold the back-bar in place as you run the screws
through the mounting plate and into the back-bar. TIE A LONG
STRING TO THE BACK-BAR so that you can easily retrieve it in
case you drop the back-bar into the wall!
3. With the Controller/Amplifier turned off, connect the CAT5 cable to the
appropriate RJ45 connector, using
Figure 7
as a guide for CAT5
termination.
4. Add or remove jumpers on the rear of the MRC44 keypad-according to
Table 1 (Keypad connections).