Model MX88
Page: 9
© 2010 Xantech LLC
Eight in-the-zone IR emitter outputs via a MX88-compatible keypad rear panel emitter
output - permitting IR commands originating in the zone to be looped back to the
zone allowing the MX88 to control components physically located in the zone.
•
Status Outputs
:
Eight zone-specific 12V status outputs
One common 12V status output (Labeled Control Out)
•
RS232/USB programming ports
(Front Panel):
Communications port used to program the system using
Universal Dragon software.
RS232 COM PORTs 1 and 2 (Rear):
Allow the MX88 to be controlled by a PC or another RS232 device, or
to control other devices that communicate via RS232 such as certain home theater components, lighting or
HVAC devices. These ports facilitate
connection to another MX88 for 16 Zones of seamless control.
Keypad connections:
One for each zone
– RJ45 connector, CAT5/5e/6/7 cable.
Ethernet port:
RJ45 connector, standard Ethernet cable (MX88vi or MX88ai only).