background image

4

RP41AV

A MULTI-ZONE SYSTEM

The following diagram illustrates a typical Multi-Zone system, using the RP41AV.

1. For simplicity, only 4 zones are shown ... many more could be added using the Xantech 796-20 Zone

Expander and more RP41AV's.

2. Using an RP41AV plus a basic power amplifier for each zone, every room in the house can have

individual source selection, volume control and room EQ (with the tone controls) at moderate cost.

3. The audio and video connections from the source components to each RP41AV (not shown), should

be made through distribution amps (such as the Xantech AV-61) to prevent distortion that may be
caused by the loading effects of multiple RP41AV's.  Refer to the AV-61 Installation Instructions for
more details.

4. For AC power management, refer to the 680-10 and Gatekeep-IR

TM 

Installation Instructions.

IR

CONFIRM

VIDEO

AUDIO

LEFT

INPUT

OUTPUT

AUDIO
RIGHT

1

2

3

4

IR

CONFIRM

VIDEO

AUDIO

LEFT

INPUT

OUTPUT

AUDIO
RIGHT

1

2

3

4

IR

CONFIRM

VIDEO

AUDIO

LEFT

INPUT

OUTPUT

AUDIO
RIGHT

1

2

3

4

SAT Receiver

AM/FM  Tuner

Left

Speaker

Right
Speaker

782-00

Power Supply

R

Home Run all

Speaker Leads

780-10

"J" Box

IR Receiver

780-10

"J" Box

IR Receiver

L

Home Run

3 Conductor

Cables

(unshielded OK)

R

L

L

Common

Sources

795-20

  ZONE CONTROLLER

1

0
9

8

7

65432

1

A

B

A

B

A

B

A

B
1

2

V

COMMON EMITTERS

ZONE EMITTERS

IR ZONE CONNECTIONS

4

321

Z

 1Z

 2

Z

 3Z

 4

Zone 1

Zone 2

Zone 3

Zone 4

490-00

Micro Link™
IR Receiver
(Cabinet Mounted)

795-20

IR Zone
Controller

R

DVD Player

R

L

XANTECH

S-62/64/66

Wall Speakers

480-00

  

Dinky Link™

IR Receiver

MAIN ROOM - ZONE 1

TV

MONITOR

Video

IN

IR

CONFIRM

VIDEO

AUDIO

LEFT

INPUT

OUTPUT

AUDIO
RIGHT

1

2

3

4

Power Supply

(included)

White Striped Side

Stereo Power Amp

RP41AV

To distribution

amplifiers, for

each source.

Repeat for each

zone.  See text,

item 3, this page.

TV

MONITOR

TV

MONITOR

ZONE 2

ZONE 3

ZONE 4

Modulator

(3-Input)

ANT. or

Cable

RF

Amp

RP41AV

RP41AV

RP41AV

Stereo Power Amp

Stereo Power Amp

Stereo Power Amp

Combiner

RF

IN

RF

IN

200-00

2-Way

Splitter

RG-6 Coax

®

RP41AV

REMOTE PREAMP

®

RP41AV
REMOTE PREAMP

®

RP41AV
REMOTE PREAMP

®

RP41AV
REMOTE PREAMP

Smart
Pad™

To 120 V AC

(unswitched)

VCR

283M 

Blink-IR™

Mouse Emitter (4)

V V G IR  IN

POWER 15VAC

V V G IR IN

POWER 15VAC

V V G IR IN

POWER 15VAC

V V G IR IN

POWER 15VAC

Fig. 4 A multi-zone 4-room system

Summary of Contents for RP41AV

Page 1: ...etting Separate Mute On Mute Off functions ensure positive mute command execution without knowing status This is helpful in remote rooms when all adjustments are made blind without any visual aids for status IR control input port connects to the emitter output of Xantech devices allowing remote control from keypads IR receivers connecting blocks etc Tone controls allow individual EQ of each zone w...

Page 2: ...ct buttons Press buttons 1 through 4 to individually select up to 4 audio video sources connected to the RP41AV 5 VOLUME Up Down buttons When pressed volume will in crease and decrease in 2 dB steps between 0 dB and 80 dB When buttons are held down the volume level will change continuously 6 MUTE ON OFF buttons Separate On Off buttons give positive mute commands without knowing what the status is ...

Page 3: ...mote commands to operate the entire system from any room For AC power management refer to the Model 680 10 Installation Instructions L R IR CONFIRM VIDEO AUDIO LEFT INPUT OUTPUT AUDIO RIGHT 1 2 3 4 480 00 Dinky Link IR Receiver 760 00 XANTECH S 62 64 66 Wall Speakers 781RG Power Supply 283M 791 44 Amplified Connecting Block 3 Conductor Cable Home Runs MAIN ROOM L Home Run Speaker Leads 780 10 J Bo...

Page 4: ...ight Speaker 782 00 Power Supply R Home Run all Speaker Leads 780 10 J Box IR Receiver 780 10 J Box IR Receiver L Home Run 3 Conductor Cables unshielded OK R L L Common Sources 795 20 ZONE CONTROLLER 10 9 8 7 6 5 4 3 2 1 A B A B A B A B 12V COMMON EMITTERS ZONE EMITTERS IR ZONE CONNECTIONS 4 3 2 1 Z 1 Z 2 Z 3 Z 4 Zone 1 Zone 2 Zone 3 Zone 4 490 00 Micro Link IR Receiver Cabinet Mounted 795 20 IR Z...

Page 5: ...l Separation 75 dB 1 kHz Freq Response 20Hz 20kHz 1 dB Bass Range 12 dB in 2 dB steps Treble Range 12 dB in 2 dB steps Video IN OUT Impedance 75 Ohms Video Insertion Loss 50 Hz 10 mHz 1 dB Video Out IN Isolation 50 Hz 10 mHz 55 dB A V Inputs Outputs RCA type phono jacks IR Code Group 40 factory preset Power Requirements 15 VAC 300 mA Power and IR Inputs 4 terminal screw terminal plug in connector ...

Page 6: ...Shell IR Red Light Output IR Red Light Output Component Side INSTALLATION ATTACHING THE EMITTERS TO IR SENSOR WINDOWS Each emitter has a clear adhesive layer on the bottom flat surface of the shell The rounded side faces the user and emits visible red light when a command is sent Fig 2 Simply peel off the adhesive cover and affix the emitter to the center of the IR sensor window on the controlled ...