background image

3

Amplifiers & Preamplifiers

ZPR68-10

7. ZONE EXPANSION PORT.  This port allows the ZPR68-10 to be linked with an EXP9 expansion

module to provide up to 15 zones of operation.  The EXP9 includes 9 slots, allowing zone XCARDs
(PCB cards) to be added one by one in the field, or purchased already installed from the factory, for
zones 7 through 15.

8. ZONE OUTPUTS.   The ZONE OUTPUTS consist of six sets of audio/video RCA type jacks - one set

for each zone.  The L and R AUDIO jacks are connected to the appropriate Left & Right input jacks
on a main power amplifier for the zone and the VIDEO jack to the composite Video input on a zone
TV monitor or modulator. Any source connected to the SOURCE INPUTS can be switched to these
ZONE OUTPUTS when the zone receives an RC68+ INPUT command at the ZONE CONTROL - IR
INPUTS.

9. SOURCE INPUTS.  The SOURCE INPUTS consist of eight sets of audio/video RCA type jacks - one

set for each input.  The L and R AUDIO jacks and the VIDEO jack are connected to the corresponding
Left & Right audio and Video output jacks (where applicable) on up to eight source components
(satellite receivers, LD players, VCR's, AM/FM tuners, CD changers, etc.).

10. POWER SUPPLY Connector.  6-Pin DIN jack permits connection of a high current multi-voltage AC

power supply (included with each ZPR68-10).

11. CO Terminals.  These two terminals provide a Control Output that goes high (+12 volts) when any zone

is first turned ON and goes low (0 volts) when the last zone is turned OFF.  Use this control voltage
to drive the voltage sensing ports of power amplifiers, such as on the PA640 and the PA1235, and/
or AC power strips to provide power on/off for the common source components and/or to drive a total
system power on/off status indicator.

12. POWER Indicator LED.  Indicates when power is applied to the ZPR68-10.  It stays on continuously

even when all zones are turned off (as long as AC power is applied to the plug-in power supply).

13. COM  PORT.  This DB9 female connector permits 2-way communications with the ZPR68-10 using

custom designed control panels or computer programs.  Port is RS-232 signal compatible, allowing
bidirectional data interface for status readout of ZPR68-10 settings as well as control of operational
functions.

COM PORT - RS232 Application Information.  Use of this port requires proficiency in computer
programming and hardware interfacing.  Refer to application Advisory, Volume 2, Number 1, for basic
communications protocol and hardware connection details.  This advisory is available on Xantech's
web site at www.xantech.com/products/alist/htm.  For more detailed information, including latest
updates, go to: http//www/xantech.com.engineerand make your selections from the list.

14. IR CONFIRM LED. Flashes when IR commands native to the ZPR68-10 are received & executed.

Won't flash when non-ZPR68-10 IR commands are passed through to operate source components,
etc.

15. Cover Panel.  Remove this to access the 8 DIP

switches for setting the power level of the
COMMON IR OUTPUTS.

16. Video Gain Adjustment Jumpers (internal).

The video gain of each zone on the ZPR68-10
can be set to two levels, by the use of an
internal jumper.  See Fig. 4 .  With the jumper
on one pin only of PJ1, the video gain is unity
(0 dB).  When the jumper is inserted onto both
pins of PJ1, the video gain is increased by +3
dB.  You should use the +3 dB position only if
you notice a reduction in picture contrast and
brightness when running long cable lengths
(usually in excess of 150 feet).  Since the majority of applications will not require additional gain, all

Zone Control
IR Input Jack

Zone A/V

Output Jacks

Video Gain

Adjustment Pins (PJ1)

Jumper

Zone PCB

Jumper

Shown in

0 dB Position

Jumper

Shown in

+3 dB Position

16

Fig. 4  Video Gain Adjustment - Jumper Locations

Summary of Contents for ZPR68-10

Page 1: ...audio source can be trimmed by the installer to prevent large volume differences when switching between sources A COM PORT using a female DB9 connector allows full control and status operations with...

Page 2: ...3 ZPR68 10 Panel Features and Functions 1 COMMON IR LEVEL DIP Switches These DIP switches set the output power level to HI or LO for emitters connected to the COMMON IR OUTPUT jacks See item 4 under I...

Page 3: ...ower is applied to the ZPR68 10 It stays on continuously even when all zones are turned off as long as AC power is applied to the plug in power supply 13 COM PORT This DB9 female connector permits 2 w...

Page 4: ...L The RC68 and the RC68 programmer available separately contains all the commands necessary to set up and operate the ZPR68 10 In addition you will need it to program the universal learning devices ac...

Page 5: ...l flat E FLAT Refer to ZONE ADJUSTMENTS procedure 13 E FLAT button Switches the tone settings to electrical flat flat frequency response and the balance to center from customized settings In conjuncti...

Page 6: ...The common CO terminal provides AC power ON OFF management for the PA640 s and for the common sources through GATEKEEP IRTM Note All source components in this typical system must have their ON OFF fun...

Page 7: ...TOR TV MONITOR SOURCE COMPONENTS L R A V Patch Cords A V Patch Cords ZONE AMPLIFIERS MODEL PA640 2 Remote ON OFF Remote ON OFF RF IN RF IN VIDEO IN TV MONITOR VIDEO IN ANT or Cable 4 Conductor Home Ru...

Page 8: ...40 Power Amplifiers and to the and terminals of the GMM1A Module of the GATEKEEP IR You may use two of the Xantech part 6015900 five foot 2 conductor cables 3 5mm mini plug on one end and stripped tin...

Page 9: ...ations However if you have a system where the total current demand does exceed 1 8 A then an external power supply s must be used to power the extra devices to prevent overheating and shutdown of the...

Page 10: ...pply of the ZPR68 10 ZONE CONTROL IR INPUTS 12V GND STATUS IR IN 9 8 6 7 4 5 2 3 1 ZPR68 10 Zone Control IR Inputs section 120 V AC Unswitched 782 00 Power Supply Smart Pad2 or 3 Four shown 780 80 J B...

Page 11: ...urces to sound equally loud when switching from one to another 1 Select the input that has the lowest apparent volume level from any zone 2 Press TRIM button This activates the TRIM mode Note TRIM mod...

Page 12: ...omplete the next step is to program the Xantech SmartPads and or learning remotes such as Xantech s URC s with the needed GATEKEEP IR ZPR68 10 and the source component commands for system operation fr...

Page 13: ...ns If an AC power line failure occurs proceed as follows after power is restored 1 Press an INPUT source button to turn any zone ON 2 Adjust VOLUME and other functions as outlined under Zone Operatiao...

Page 14: ...her zone s as well Zone to zone IR cross talk The IR output from the emitters connected to the Common IR Outputs attached to the common components e g tape VCR tuner etc may be radiating into the IR s...

Page 15: ...and GND on each of the offending zones Refer to Fig 7 under INSTALLATION section for details The capacitance of the shielded cable prevents high bit rate commands from passing through unaltered The r...

Page 16: ...s Audio L R Zone Outputs Video Treble Bass LMC1982 LPF Level Volume Balance X1 X0 5 X 2 X 2 Buffer Buffer Buffer Buffer Video Gain Adjust Jumper 0 dB 3 dB Common IR Level LO H I IR Confirm CO G Zone I...

Reviews: