background image

8

2. Connect the audio and video Output jacks on each of the audio/video source components to the

SOURCE INPUTS jacks on the ZPR68-10.

Use high quality audio and video RCA-type patch cords.

3. Place a model 283M Blink-IR Emitter on the IR sensor window of each source component, and plug

them into the IR OUT on the appropriate GATEKEEP-IR modules.  Connect one of the COMMON IR
OUTPUTS on the ZPR68-10 to the IR IN of the GMM1A module on the GATEKEEP-IR.

4. In cases where you may connect emitters directly to the COMMON IR OUTPUTS, you may need to

change the COMMON IR LEVEL DIP switch settings (item #1).  To do so,  remove Cover Panel (item
#15).  All are set to the LO position at factory.

Consider the following factors when choosing HIgh or LOw power settings for the source emitters:

a) In the majority of cases, when you mount an emitter on the IR sensor window of the controlled

device, you would use the LOw power mode.  This prevents overload of high gain sensor circuits,
for best operation.

 b) The HIgh power mode may be used when you mount the high output 282M emitters on an adjacent

shelf or door a short distance from the unit's sensor. Another instance is when you place an emitter
inside the device, but cannot place it close to the IR sensor.  In such cases, you may need the high
power setting to blast through printed circuit boards or around chassis structures, etc.  In addition,
when using the lower output 283M and 286M Blink IR's, you may need the high power mode for
some devices that have less sensitive IR sensors.

5. Connect the common CO and G terminals (item #11, located just under the POWER indicator) to the

REMOTE ON/OFF inputs on the two PA640 Power Amplifiers and to the + and  terminals of the
GMM1A Module of the GATEKEEP-IR.

You may use two of the Xantech part #6015900 five foot 2-conductor cables (3.5mm mini plug on one
end and stripped tinned ends on the other) for connection to the PA640's. Connect the white-striped
side to CO and the other to G.

6. Connect the AUDIO L and R ZONE OUTPUT  jacks on the ZPR68-10 to the CH1CH2, etc., LINE

INPUT jacks on each of the PA640 Power Amplifiers.

Use high quality audio RCA type patch cords. You may connect the L channels from the ZONE
OUTPUTS
 on the ZPR68-10 to CH1CH3 & CH5, respectively, on the PA640 's and the R channels
to CH2CH4 & CH6.  Be sure to follow this through when connecting the speaker leads so that the L
and R channels are correctly connected to the Left and Right speakers in the rooms.

7. Connect the VIDEO outputs from Zones 3 and 6 to a Video Input on the TV monitors in zone rooms

3 and 6.

Use RG-6 coaxial cable with RCA type phono plugs on each end. You may need to adjust the Video
Gain on the zone cards if you have coaxial cable runs greater than 150 feet.  See Fig. 4 for details.

8. Connect the VIDEO outputs from Zones 2 and 4 to the Video Inputs of a 2-Input Modulator.

Use high quality RCA type video patch cords.

9. Make the necessary connections of the Modulator to the Combiner, Cable System, Splitter, etc.

Use RG-6 coaxial cable with "F" connectors on each end to connect each device, including the coaxial
cables going to the RF IN on the room TV's in Zones 2 and 5.

10. Connect the speaker leads from each Zone room to the corresponding SPEAKERS terminals on the

PA640 Power Amplifiers.

Be sure to observe correct L and R channel assignment and speaker phasing (+ and ).  Use 14 gauge
speaker wire for lengths up to 200 feet.

11. Plug the Power Supply (included with the ZPR68-10) into the DIN jack marked POWER SUPPLY (item

#10).

ZPR68-10

Summary of Contents for ZPR68-10

Page 1: ...audio source can be trimmed by the installer to prevent large volume differences when switching between sources A COM PORT using a female DB9 connector allows full control and status operations with...

Page 2: ...3 ZPR68 10 Panel Features and Functions 1 COMMON IR LEVEL DIP Switches These DIP switches set the output power level to HI or LO for emitters connected to the COMMON IR OUTPUT jacks See item 4 under I...

Page 3: ...ower is applied to the ZPR68 10 It stays on continuously even when all zones are turned off as long as AC power is applied to the plug in power supply 13 COM PORT This DB9 female connector permits 2 w...

Page 4: ...L The RC68 and the RC68 programmer available separately contains all the commands necessary to set up and operate the ZPR68 10 In addition you will need it to program the universal learning devices ac...

Page 5: ...l flat E FLAT Refer to ZONE ADJUSTMENTS procedure 13 E FLAT button Switches the tone settings to electrical flat flat frequency response and the balance to center from customized settings In conjuncti...

Page 6: ...The common CO terminal provides AC power ON OFF management for the PA640 s and for the common sources through GATEKEEP IRTM Note All source components in this typical system must have their ON OFF fun...

Page 7: ...TOR TV MONITOR SOURCE COMPONENTS L R A V Patch Cords A V Patch Cords ZONE AMPLIFIERS MODEL PA640 2 Remote ON OFF Remote ON OFF RF IN RF IN VIDEO IN TV MONITOR VIDEO IN ANT or Cable 4 Conductor Home Ru...

Page 8: ...40 Power Amplifiers and to the and terminals of the GMM1A Module of the GATEKEEP IR You may use two of the Xantech part 6015900 five foot 2 conductor cables 3 5mm mini plug on one end and stripped tin...

Page 9: ...ations However if you have a system where the total current demand does exceed 1 8 A then an external power supply s must be used to power the extra devices to prevent overheating and shutdown of the...

Page 10: ...pply of the ZPR68 10 ZONE CONTROL IR INPUTS 12V GND STATUS IR IN 9 8 6 7 4 5 2 3 1 ZPR68 10 Zone Control IR Inputs section 120 V AC Unswitched 782 00 Power Supply Smart Pad2 or 3 Four shown 780 80 J B...

Page 11: ...urces to sound equally loud when switching from one to another 1 Select the input that has the lowest apparent volume level from any zone 2 Press TRIM button This activates the TRIM mode Note TRIM mod...

Page 12: ...omplete the next step is to program the Xantech SmartPads and or learning remotes such as Xantech s URC s with the needed GATEKEEP IR ZPR68 10 and the source component commands for system operation fr...

Page 13: ...ns If an AC power line failure occurs proceed as follows after power is restored 1 Press an INPUT source button to turn any zone ON 2 Adjust VOLUME and other functions as outlined under Zone Operatiao...

Page 14: ...her zone s as well Zone to zone IR cross talk The IR output from the emitters connected to the Common IR Outputs attached to the common components e g tape VCR tuner etc may be radiating into the IR s...

Page 15: ...and GND on each of the offending zones Refer to Fig 7 under INSTALLATION section for details The capacitance of the shielded cable prevents high bit rate commands from passing through unaltered The r...

Page 16: ...s Audio L R Zone Outputs Video Treble Bass LMC1982 LPF Level Volume Balance X1 X0 5 X 2 X 2 Buffer Buffer Buffer Buffer Video Gain Adjust Jumper 0 dB 3 dB Common IR Level LO H I IR Confirm CO G Zone I...

Reviews: