AC Distribution Panels
Most systems incorporate distribution centers both ahead of the
Freedom X (the AC source panel) and between the Freedom X and
the loads (the AC load panel). An AC source panel includes a main
circuit breaker, which serves as over-current protection and as a
disconnect for the AC shore power supply line. Additional circuit
breakers serve individual circuits, one of which serves the Freedom
X. The AC load panel can incorporate an AC output circuit breaker
and breakers for individual load circuits.
AC Cabling
AC cabling includes all the wires and connectors between the AC
source and the Freedom X, as well as all cabling between the
Freedom X and the AC output panels, circuit breakers, and loads.
The type and size of the wiring varies with the installation and load.
For example, in high vibration environments, such as marine or RV
applications, wire nuts may not be acceptable, so crimp splices
would be required. In other applications, flexible multiple-strand
wire may be required. Installation codes usually specify solid or
stranded, overall size of the conductors, and type and temperature
rating of the insulation around the wire. Cord must be of type S, SE,
SEOO, SO, ST, STO, SJ, SJE, SJEOO, SJT or SJTO.
AC breakers and fuses must be sized to adequately protect the
wiring that is installed on the input and output AC circuits of the
Freedom X. All breakers and wiring must be sized and connected in
accordance with the electrical codes or regulations applicable to
your installation. Table 1 gives some examples of wiring sizes based
on the U.S. National Electrical Code and the Canadian Electrical
Code. These examples are based on using a two-conductor-plus-
ground cable rated at 75
°
C, and assuming an ambient temperature
of up to 30
°
C. Ensure that your breakers and fuses have suitable
temperature ratings for your wiring. Other codes and regulations
may also be applicable to your installation.
Table 1
Required AC Wire Size vs Breaker Rating
Breaker Size (amps)
10A
15A
20A
30A
Minimum Wire Size
14AWG
14AWG
12AWG
10AWG
NOTICE
RISK OF DAMAGE TO THE INVERTER
Do not connect the Freedom X to a 120/240V, 3-pole, 4-wire circuit.
Failure to follow these instructions can damage the unit and/or equipment.
Freedom X Owners Guide.book Page 12 Wednesday, May 11, 2016 10:32 AM
Summary of Contents for 806-1212
Page 2: ...Freedom X Owners Guide book Page ii Wednesday May 11 2016 10 32 AM ...
Page 12: ...Freedom X Owners Guide book Page x Wednesday May 11 2016 10 32 AM ...
Page 14: ...Freedom X Owners Guide book Page ii Wednesday May 11 2016 10 32 AM ...
Page 77: ...Freedom X Owners Guide book Page i Wednesday May 11 2016 10 32 AM ...