AC and DC Panel
975-0822-01-01
7
Item
Description
7
DC terminal
opening for routing (+) positive DC cable.
8
LED alert indicator
for reverse DC polarity.
9
AC output terminal opening
for routing AC output wiring.
10
AC input terminal opening
for routing AC input wiring.
11
c
Reserved for future use.
AC cover.
12
Mounting flanges
on both sides allow you to mount the
inverter permanently on the interior deck or on a wall.
13
Ventilation grille
(openings) must not be obstructed for
the proper operation of the cooling fan and inverter. When
the inverter is mounted, the ventilation grille must not point
up or down.
Cooling fans
turn on when the internal temperature
reaches a set point temperature.
14
c
Reserved for future use.
Supplementary protector
with reset button.
15
AC Out Neutral-to-Earth Bond
. See
Bonding Option (Earth Relay Function)" on page 17
for
more information.
WARNING
ELECTRICAL SHOCK HAZARD
n
Use a torque screwdriver to tighten the bolt on the DC
earth lug to a torque of 2.6 N-m of force.
n
Apply an anti-corrosion compound to the copper wire prior
to connecting to the DC earth lug.
Failure to follow these instructions can result in death, serious
injury, or equipment damage
.