Basic Installation Procedures
32
Freedom X 2000 - 230V Owner's Guide
WARNING
FIRE HAZARD
Do not complete the next step if flammable fumes are present.
Explosion or fire may result if the disconnect/battery selector switch
is not in the off position. Thoroughly ventilate the battery
compartment before making this connection.
Failure to follow these instructions can result in death, serious
injury, or equipment damage
.
13. Route the negative cable through the right side strain relief
clamp and connect the cable from the negative post of the
battery to the negative DC terminal of the inverter.
14. Fasten the DC terminal nut (set aside earlier) to the terminal
bolt. Tighten the nut to a torque of 8–9 N-m of force. Do not
overtighten. Make the connection snug enough so the cable
lug does not move around on the DC terminal. Center it
through the DC knockout hole and do not let it touch the
edge.
15. Replace the wiring compartment cover by tightening the
captive nut panel screw. See the following electrical shock
hazard warning.
WARNING
ELECTRICAL SHOCK HAZARD
Use a torque screwdriver to tighten the captive nut panel screw to
0.56 N-m torque of force to ensure a proper earth connection and a
required tool access to the wiring compartment.
Failure to follow these instructions can result in death, serious
injury, or equipment damage
.
Summary of Contents for 817-2000-12
Page 1: ...Freedom X 2000 230V Inverter Owner s Guide Freedom X 2000 230V 817 2000 12 ...
Page 12: ...This page is intentionally left blank 2 ...
Page 24: ...This page is intentionally left blank 2 ...
Page 52: ...This page is intentionally left blank 2 ...
Page 77: ...This page is intentionally left blank 2 ...