Adjusting Settings in Configuration Mode
50
Freedom X 2000 - 230V Owner's Guide
Setting Name
Setting
Number
Default
Value
Range of
Values
Description
Inverter Shutdown
Recovery
13
MAT
At0
(auto-
restart)
MAT
(manual
restart)
The inverter shuts down when there is an over temperature,
overload, and short circuit condition. Selecting
ATO
(auto-restart)
will allow the inverter to recover automatically from a shutdown up
to three times maximum. Selecting
MAT
(manual restart) allows the
user to restart the inverter by performing a manual reset, that is, by
acknowledging the restart via the display panel.
Audible Alarm
14
bON
bON
(Audible)
BOF
(Mute)
The alarm beeps once every 5 s.
Reset all settings to their
default values
99
ndf
NDF
(as is)
DEF
(default)
ndF
refers to current settings.
Choose
def
to restore all settings to their default values.