26
XPLORE 120/12 Battery Charger Owner's Guide
Step 3: Installing DC Wiring
The procedure for installing the DC wiring applies to a single
battery, as well as multiple batteries or battery banks.
WARNING
ACCIDENTAL SHORT OR SPARK HAZARD
Leave the DC disconnects or breakers in the Off position or DC
fuses removed from their fuse holders until installation is complete.
Failure to follow these instructions can result in death, serious
injury, or equipment damage
.
1. Remove the wiring compartment cover.
NOTE
: Use a Philips #2 (3.5mm) screwdriver to loosen (
but not to
remove
) the captive nut panel screw(s). One to two full turns are
enough to loosen it.
1. Plan the route that the DC wires will follow, keeping it as
short as possible. Measure and cut the required wire length,
after allowing some extra length for connections and to
provide slack in the wires for strain relief.
2. Identify the positive cables, by using color-coded wire, or by
marking both ends of the cable with colored tape, or similar
kind of marking. Repeat with a different color for the
negative. Most installation codes recommend coloring the
positive red and the negative black.
NOTE
: You may find it helpful to label each cable, associating it
with the battery bank it is connected to. For example, NEG (–),
BAT1, BAT2, and so on.
3. Install a DC circuit breaker or a DC fused disconnect in
each positive cable that is as close to the battery positive
terminal as possible.
Consult your local electrical codes regarding the distance
allowed between the battery and the fuse or breaker. Be
sure the breaker or fused disconnect is open.
4. Route the wiring to the batteries and to the XPLORE
Charger. Avoid routing wiring through an electrical
distribution panel, battery isolator, or other device that will
add voltage drops.
Summary of Contents for 819-0120-12
Page 1: ...XPLORE 120A 12V Battery Charger Owner s Guide Model XPLORE 120 12 Battery Charger 819 0120 12...
Page 12: ...This page is intentionally left blank 2...
Page 18: ...This page is intentionally left blank 2...
Page 24: ...This page is intentionally left blank 2...
Page 60: ...This page is intentionally left blank 2...
Page 72: ...975 1038 01 01 Rev C 31021 http www xantrex com 1 800 670 0707 1 408 987 6030 Printed in...