Troubleshooting
975-1038-01-01
49
Troubleshooting
In the event that you have a problem with your XPLORE Charger,
the following tables will help you to identify the problem and offer
possible solutions to the problem. For more help not covered in
this section, please contact http://www.xantrex.com/power-
products-support/.
Symptom
Indicator LEDs do not illuminate when charger is connected to an
AC power source.
Possible Cause
Solution
No power at AC (mains)
source.
Ensure that power is available at
charger AC input and it is within
acceptable range.
Defective AC wiring or
switches/breakers
Wiring and wiring components
must be inspected and replaced
by a qualified installer.
Symptom
The initial power up display test is not performed upon connection
of battery or batteries.
Possible Cause
Solution
XPLORE Charger does not
detect battery for one of the
following reasons:
- poor connection
- reverse polarity connection
(blown fuse)
- damaged wiring
- open DC breaker or external
fuse
- battery voltage is below 9 V
Check quality of battery
connection and wires.
Ensure correct polarity (negative
connected to negative, positive
connected to positive).
In case there is an accompanying
fault, check the type of fault from
the Xantrex App.
Summary of Contents for 819-0120-12
Page 1: ...XPLORE 120A 12V Battery Charger Owner s Guide Model XPLORE 120 12 Battery Charger 819 0120 12...
Page 12: ...This page is intentionally left blank 2...
Page 18: ...This page is intentionally left blank 2...
Page 24: ...This page is intentionally left blank 2...
Page 60: ...This page is intentionally left blank 2...
Page 72: ...975 1038 01 01 Rev C 31021 http www xantrex com 1 800 670 0707 1 408 987 6030 Printed in...