Installing the Freedom Sequence
This
gu
id
e for
us
e by qu
alifi
ed installers only.
Step 2: Connecting the AC Main wires
Figure 7
Install the AC Strain Relief Devices
Locate the two AC Main cable holes—one on each side of the power manager. Starting on one side,
(1)
insert the threaded strain relief clamp into the cable hole.
(2)
Screw the ring fastener onto the
threads to secure the strain relief clamp in place. Repeat (1) and (2) on the other side.
(3)
Loosen the
screws of the strain relief clamp to allow the AC cable to be passed through.
Figure 8
Connect the Input and Output AC Main Wires
L1
N
L2
G
10mm
AC Main wires
L1
N
L2
G
A
C
Cable
MAIN AC
PANEL
(1)
Strip the phase and neutral wires of the AC Main cables as shown above. If the ground wire is
jacketed instead of bare, strip it as well as shown above.
(2)
Connect each wire of the AC cable meant
for the breakered AC transfer switch correspondingly into each slot on the power manager’s AC
terminal block. Use the recommended torque of between 18.0–20.0 Nm. Do not overtighten.
(3)
Connect each wire of the AC cable meant for the main AC panel correspondingly into each slot
on the power manager’s terminal block. Use same torque as (2).
(4)
Connect the wires properly from
the other end of the AC cable in (2) to the AC transfer switch.
(5)
Connect the wires properly from the
other end of the AC cable in (3) to the main AC panel’s input line.
NOTE
: In some cases, (1) to (3) are all that’s needed when (4) and (5) have already been done from
a previous installation.
FSequence IPM Install Guide.book Page 13 Thursday, October 6, 2011 3:21 PM
Summary of Contents for Freedom Sequence
Page 2: ...FSequence IPM Install Guide book Page ii Thursday October 6 2011 3 21 PM...
Page 10: ...FSequence IPM Install Guide book Page ii Thursday October 6 2011 3 21 PM...
Page 30: ...FSequence IPM Install Guide book Page 20 Thursday October 6 2011 3 21 PM...
Page 31: ...FSequence IPM Install Guide book Page i Thursday October 6 2011 3 21 PM...