Basic Installation Procedures
975-0787-01-01
29
Figure 8 Loosening the captive nut panel screw
1
1
Captive nut panel screw
4. Strip a single AC input wire, as appropriate. Strip 10 mm off
the ends of each of the three the wires (tin the exposed
copper wire with lead-free solder using a soldering iron).
5. Remove the knockout and install a ½" (or ¾"
f
) strain relief
clamp.
6. Route the wires through the strain relief clamp (not shown in
the figure).
f
Available only to Freedom X 3000 120VAC 12VDC.
Figure 9 Routing the wires
N
L
G
N
L
G
N
L
G
2
1
3
4
5
1
step 8a
2
step 8b
3
step 8c
4
10mm
5
to circuit breaker
NOTE
: AC input hole - install a strain relief clamp (not shown).
7. Locate the Neutral, Ground and Line terminals on the AC
input terminal labeled as
N
,
G
, and
L
respectively.