Adjusting Feature Settings in Configuration Mode
975-0787-01-01
53
Setting Name
Setting
Number
Default
Value
Range of
Values
Description
LBCO Recovery Voltage
(12VDC models)
04
13
.
1
10
.
2
to
16
.
0
and
OFF
The range is from LBCO v 0.2 to 16, adjusted by 0.1
increments. Selecting
OFF
or a higher value than the battery’s
actual fully-charged voltage level will disable the auto-recovery
feature. You may manually reset the inverter when the low battery
cut off event occurs.
LBCO Recovery Voltage
(24VDC model)
26
.
2
20
.
2
to
32
.
00
and
OFF
The range is from LBCO v 0.2 to 32, adjusted by 0.1
increments. Selecting
OFF
or a higher value than the battery’s
actual fully-charged voltage level will disable the auto-recovery
feature. You may manually reset the inverter when the low battery
cut off event occurs.
Power Save Time
05
25
OFF, 1 to 25
The range is from 1 to 25, adjusted by 1-hour increments. The next
setting after 25 is OFF.
Power Save (Load
Sensing) Mode
06
dIs
ENA
(enable)
,
DIS
(disable)
When enabled, the inverter’s “no load” loss can be reduced further
when total load is less than 25 watts.
Output Frequency
07
60
60
50
After changing the output frequency setting, turn the unit off and
then on again, in order for the change to take effect.
Output Voltage
08
120
120
110
108