System Specifications
80
Freedom X Owner's Guide
System Specifications
Freedom X 1000 120VAC 12VDC
Freedom X 2000 (Both 12 &
24VDC models)
Freedom X 3000 120VAC 12VDC
Transfer relay rating (A
a
)
30A
30A
30A
Transfer time (milliseconds
b
)
Shore to inverter:
Inverter to shore:
<20 milliseconds
<20 milliseconds with a 20-
second delay
<20 milliseconds
<20 milliseconds with a 20-
second delay
<20 milliseconds
<20 milliseconds with a 20-
second delay
Transfer voltage (V)
Shore to inverter:
Inverter to shore:
<85 V and >140 V
<135 V and >90 V
<85 V and >140 V
<135 V and >90 V
<85 V and >140 V
<135 V and >90 V
Cooling
Fan, activated by any of the
following:
High internal temperature
High AC output power
Fan, activated by any of the
following:
High internal temperature
High AC output power
Fan, activated by any of the
following:
High internal temperature
High AC output power
Table 17 System specifications
a
Circuit breakers shall not carry more than 80% of their UL rating continuously.
b
To change the AC Transfer time (mode), see
.