Basic Installation Procedures
40
Freedom X Owner's Guide
Testing in Battery Mode
To test the Freedom X:
1. For hard wired installations, ensure shore power is not
present.
2. Press the Power button to turn the inverter on.
The green status indicator LED for Battery mode (Inverter
mode) is illuminated. See
Status LED Indicators on page 44
.
3. Plug a test load, such as a lamp within the power rating of
the inverter into the Freedom X GFCI or an AC outlet hard
wired to the Freedom X.
4. Turn the lamp on to verify that it operates.
If the lamp operates, your installation is successful. If your
installation has AC input and output hard wired to the Freedom X,
proceed to
If the status LED on the display panel glows red, see the
Troubleshooting chapter.
Testing in Grid Mode
To test the Freedom X:
n
With the test load from the previous test still connected and
operating, connect the shore power source.
n
The Freedom X transfers the test load to shore power. The
green LED indicating grid mode turns on and the LCD screen
displays the
AC MODE
icon.
n
If the test load operates, your installation is successful.
NOTE
: If the Power button on the Freedom X is turned ON, the
Freedom X will automatically supply the appliances with inverter
power if the shore power source fails or becomes disconnected.
If the Power button on the Freedom X is turned ON and shore
power voltage is too low (less than 90 volts AC), the unit will
transfer to inverter power to continue running your appliances.
NOTE
: Whether or not the Power button is turned ON, shore
power will pass through the Freedom X to the output when shore
power is within normal operating range.
NOTE
: In the event of low or no battery voltage, shore power will
pass through the Freedom X to the output even when shore power
is outside the normal operating range.