Installation
3–14
975-0289-01-01
AC Input and Output Wiring from a Generator
Figure 3-12
Connecting the AC Input and Output from a Generator
This 15 A circuit breaker is only
required if the generator being
used doesn’t already have one.
Connect the PowerHub to a
15 A circuit breaker in the AC
Distribution Panel. This AC
Distribution Panel may not be
fed with any other AC sources.
Torque Neutral and Line
terminals to 1.3 nm (11.5 in-lbs)
Torque Ground terminal
to 1.8 nm (16.0 in-lbs)
Torque Neutral and Line
terminals to 1.3 nm (11.5 in-lbs)
Torque Ground terminal
to 1.8 nm (16.0 in-lbs)