Introduction
2
975-0264-01-01 Rev A
Features
The RC8 Remote Control duplicates the ON/OFF power
switch on the inverter and displays general system operating
parameters.
The remote can operate the inverter from distances of up to
100 feet and connects directly to the inverter’s “RC8
Remote” or “COM” port using a special, tinned, 6-conductor
length of cable.
The RC8 Remote Control is compatible with DR Series,
Legend Series I, Voyager Series, M1512/1524 Series, Truck
Series I, TS Series, UX Series, and PS Series inverters.
The RC8 Remote Control includes the following features.
•
Easy-to-Read LED
•
Front Panel Control
•
Plug-in Installation
•
ROF - Remote Override Function (Legend Series I,
Truck Series I, and UX Series inverters only)
The following system operating parameters are displayed
with a single LED.
•
Inverter Status (ON/OFF)
•
Inverter/Charger Indicator
•
Search Mode Indicator
•
Error Indicator
Figure 2
The RC8 Remote Control Features
LED
ON/OFF Button
Operation
975-0264-01-01 Rev A
11
PS Series Inverters
When the RC8 is used with PS Series inverters, its red LED
will display the following.
•
Solid
With AC line power present, the unit is charging the
batteries while directing AC to the load. With no AC line
power present, the inverter is running on the batteries and
supplying AC to the load.
•
Blinking Slow (1 to 2 flashes @ 1 second intervals)
The inverter is in search mode (no load connected).
•
Flickering*
The inverter has detected an overcurrent error. The LED
(and inverter) will turn OFF whenever an overcurrent
condition exceeds eight seconds.
•
OFF*
The inverter is OFF or an error condition caused by
overheating, low battery voltage, or high battery voltage
has occurred.
Important:
If the LED does not come back on after pressing
the ON/OFF switch on the RC8, the error condition may not have
cleared. Check the inverter’s error indicator and consult the
operator’s manual for recommendations.
Summary of Contents for RC8
Page 2: ......