Operation
Accumulated Status, Status, and Fault Registers
48
Operating Manual for RS-232 for XPD Series Power Supply
Table 3.8
Accumulated Status, Status, and Fault Registers
Notes:
1.
All mnemonics can be masked or unmasked.
2.
The error (ERR) bit is reset in the accumulated status, status, and serial poll registers with an
error query (ERR?).
3.
The accumulated status register is cleared with an accumulated status query (ASTS?).
4.
A fault is cleared with a fault query (FAULT?).
Condition
Mnemonic Bit Position Bit Weight
Constant voltage operation
CV
0
1
Constant current operation
CC
1
2
Not used
–
2
4
Overvoltage protection tripped
OV
3
8
Over temperature protection tripped
OT
4
16
Supply external shutdown active (J21-1)
SD
5
32
Foldback mode operation
FOLD
6
64
Remote programming error
ERR
7
128
Power ON (accumulated status, status
registers only)
PON
8
256
Remote mode (accumulated status, status
registers only)
REM
9
512
AC fail condition
ACF
10
1024
Output fail condition
OPF
11
2048
Sense protection tripped
SNSP
12
4096
Summary of Contents for RS232-XPD