3.0 OPERATION
48
©2000 Xantrex Technology Inc.
Front Panel Controls and Indicators
(continued)
Circuit Breakers
The DR inverter/charger contains two circuit breakers located on the right-hand side of the
chassis, directly above the AC input terminal block. The pass-through AC input circuit breaker
protects the AC wiring and connected load. The charger AC input circuit breaker protects the
charger circuit. The breakers are rated for the maximum charge rate and pass-through current
allowed according to the rating of the internal relay.
Table 11
Battery Charger Circuit Breakers
Table 10
AC Pass-through Circuit Breakers
AC Pass-through
Circuit Breaker
Charger AC Input
Circuit Breaker
Figure 43
AC Pass-through and Charger AC Input Circuit Breakers
Models
DR15xx
DR24xx
DR36xx
120 VAC
30 amps
30 amps
30 amps
240 VAC
15 amps
15 amps
N/A
Models
DR15xx
DR24xx
DR36xx
120 VAC
20 amps
30 amps
30 amps
240 VAC
8 amps
15 amps
N/A