Analog Programming Mode
M370078-01
4-17
4
Resistive-Controlled Current APG Setup
To activate APG current mode using an external resistor source:
1. Turn the 9-position mode control to the CAP position to press the
rotary Adjust/Enter control if the control knob is already at CAP
position.
CAPr
is displayed on the output voltage display.
2. Turn rotary Adjust/Enter control to select
Rn1S
(voltage source from
non-isolated connector).
3. Press the rotary Adjust/Enter control to commit the selected mode.
LE C
is displayed on the output voltage display.
4. Once the desired level has been selected, press the rotary Adjust/Enter
control to commit the change.
The display will return to the normal display.
Deactivating APG Current Mode
To deactivate the APG current mode:
1. Turn the 9-position mode control to the CAP position or press the
rotary Adjust/Enter control if the mode control is already at the CAP
position.
2.
CAPr
is displayed on the output voltage display.
3. Turn the rotary Adjust/Enter control to select
nonE
.
4. Press the rotary Adjust/Enter control to commit the change.
The display will return to the normal display.