Operation
Power Supply Operation
Release 3.0
103
The slew rate error increases as the slew rate increases.
Selecting
SLEW RATE
from the main menu will give you two choices:
Voltage slew -
adjust the voltage slew rate
Voltage default -
restore the default voltage slew rate
Selecting
VOLTAGE DEFAULT
will return the slew rate to the default value of
1% rated voltage per 150us.
To set the slew rate:
The combination must not exceed 1%/30us. Though the software will attempt to
achieve higher slew rates, it is limited to this value by hardware constraints. The
power supply slew rate cannot be faster than the rise and fall times given in the
product specifications on page 228. Manufacturer's recommendation is to keep the
slew rate at or below the default value.
Step # Do This
You Will See
1
ERROR MSGS
2
Use the scroll keys to get the SLEW
RATE menu.
SLEW RATE
3
Voltage slew
4
dV: 0.100 V
5
Enter the desired voltage step.
Allowable range is 0.1% to 5% rated
voltage.
dV: 1.000 V
6
dt: 150 us
7
Enter the time interval. The range is
150 us to 1.5 s.
dt: 1000 us
8
MENU
ENTER
ENTER
ENTER
ENTER
Summary of Contents for XDC
Page 2: ......
Page 3: ...Operating Manual for XDC 6000 Watt and 12000 Watt Series Digital Programmable DC Power Supply ...
Page 22: ...List of Figures xx Operating Manual for XDC Series Power Supply ...
Page 180: ...Current Sharing 6000 Watt only Operation 178 Operating Manual for XDC Series Power Supply ...
Page 216: ...SCPI Command Reference Expressions 214 Operating Manual for XDC Series Power Supply ...
Page 228: ...GPIB Performance Specifications 226 Operating Manual for XDC Series Power Supply ...
Page 253: ......