Remote Operation
RS-232 Operation
118
Operating Manual for XDC Series Power Supply
RS-232 Operation
RS-232
Connection
Use a standard null modem cable to connect the power supply to the host interface.
The RS-232 port is a standard male DB9 connector. Table 4.6 describes the pin
functions. Pins 1, 4, 6, and 9 are not used.
Table 4.6
RS-232 Pins
Configuration
Front Panel
First set the RS-232 parameters:
Pin #
Function
1
Not used
2
Receive
3
Transmit
4
Not used
5
Ground
6
Not used
7
Ready to Send (RTS)
8
Clear to Send (CTS)
9
Not used
Step # Do This
You Will See
1
ERROR MSGS
2
5 times
REMOTE CONFIG
3
RS-232 Cfg
4
Baud 9600
5
or
Select the baud rate.
Baud #####
6
Flow Ctl None
7
or
Select the flow control option.
Options are
None
= no flow control
Hdwr
= CTS/DTS hardware
handshake
XON
= software, XON/XOFF
characters used
8
Settings are saved.
MENU
ENTER
ENTER
ENTER
ENTER