Current Sharing (6000 Watt only)
Overview
174
Operating Manual for XDC Series Power Supply
Configure
Current
Share
Current sharing may be configured either by SCPI commands sent via a remote
interface or by using the Front Panel. The current sharing modes available are:
•
No sharing
•
Master:
sets up the unit as the master controller.
•
Slave:
sets up the unit as the controlled slave.
Front Panel
In addition to selecting the current share mode, the master may be set up to display
the summed current from all units.
On the front panel, a
MASTER
or
SLAVE
annunciator will light up to indicate the
current share mode.
To configure current share with the front panel:.
Step # Do This
You Will See
1
ERROR MSGS
2
or
Press 7 times
CURRENT SHARE
3
No share
4
or
to select the current
share option (No share, Master or Slave).
Press
to save.
If No share or Slave are selected,
configuration is complete and the menu
exits.
Master
4a
If Master has been selected, you will be
prompted to select whether the master
should display the total current output of all
current share units.
Use
or
to select Y or N.
Press
Display Sum? Y
MENU
MENU
ENTER
ENTER
ENTER
Summary of Contents for XDC
Page 2: ......
Page 3: ...Operating Manual for XDC 6000 Watt and 12000 Watt Series Digital Programmable DC Power Supply ...
Page 22: ...List of Figures xx Operating Manual for XDC Series Power Supply ...
Page 180: ...Current Sharing 6000 Watt only Operation 178 Operating Manual for XDC Series Power Supply ...
Page 216: ...SCPI Command Reference Expressions 214 Operating Manual for XDC Series Power Supply ...
Page 228: ...GPIB Performance Specifications 226 Operating Manual for XDC Series Power Supply ...
Page 253: ......