Specifications and Characteristics
Electrical Specifications—Summary
Release 3.0
233
Table E.6
Drift Specifications for 12000 Watt units (10V to 60V Models)
Models
10–1200
20–600
30–400
40–300
60–200
Drift (30 minutes):
1
Voltage (0.04% of Vmax)
Current (0.6% of Imax)
1. Maximum drift over 30 minutes with constant line, load, and temperature, after power on.
4 mV
7200 mA
8 mV
3600 mA
12 mV
2400 mA
16 mV
1800 mA
24 mV
1200 mA
Drift (8 hours):
2
Voltage (0.02% of Vmax)
Current (0.05% of Imax)
2. Maximum drift over 8 hours with constant line, load, and temperature, after 30 minute warm-up.
2 mV
600 mA
4 mV
300 mA
6 mV
200 mA
8 mV
150 mA
12 mV
100 mA
Temperature Coefficient:
3
Voltage (0.04% of Vmax/°C)
Current (0.06% of Imax/°C)
3. Change in output per
°
C change in ambient temperature, with constant line and load.
4 mV
720 mA
8 mV
360 mA
12 mV
240 mA
16 mV
180 mA
24 mV
120 mA