Specifications and Characteristics
Output Performance Specifications
240
Operating Manual for XDC Series Power Supply
User Line Interface
Includes auxiliary status lines, interlock, and external trigger lines.
Switching Frequency
Typical 31 kHz; 62 kHz output ripple
Rise Time
5 to 95% step in output voltage.
Fall Time
For a programmed 95% to 5% step in output voltage.
Time Delay From Power On Until Output Stable
5 s maximum
(Within regulation envelope)
Time Delay From Output Enable Until Output Stable
2 s maximum
(Within regulation envelope)
Output Hold-Up Time – Power Off
Minimum 4 ms (at full load)
Maximum Current Sink
Capability, Each Output
10 mA
Maximum Supply Voltage
15 V
dc
Minimum Supply Voltage
4 V
dc
Isolation
300 Vdc with respect to chassis
potential or negative output
Load Condition
Time (Max)
No Load
100 ms
Full Load
100 ms
Load Condition
Time (Max)
No Load
1
1. Fall time is
≤
4s for 300 V and 600 V units.
3 s
Full Load
50 ms