Operation
Power Supply Operation
68
Operating Manual for XDC Series Power Supply
These 2 extra steps are shown in the following example.
To set the Under-Voltage Protection:
To set the Over-Current Protection:
Step # Do This
You Will See
1
OVP SET 0V
2
Press repeatedly until the
desired setting appears.
UVP SET 0V
3
UVP SET 0V
4
Use the Voltage knob, the numeric
keypad, or the arrow keys to enter a
value (0–103% of the unit’s rated
voltage).
UVP SET ####V
5
S/D if trip? N
6
Use the arrow keys to select Yes or
No. For this example, Yes is selected.
S/D if trip? Y
7
This setting is saved and the display
returns to its default operating mode.
Step # Do This
You Will See
1
OVP SET 0V
2
Press repeatedly until the
desired setting appears.
OCP SET 0A
3
OCP SET 0A
4
Use the Current knob, the numeric
keypad, or the arrow keys to enter a
value (0–103% of the unit’s rated
current).
OCP SET ####A
5
S/D if trip? N
6
Use the arrow keys to select Yes or
No. For this example, Yes is selected.
S/D if trip? Y
7
This setting is saved and the display
returns to its default operating mode.
PROT SET
ALARMS
PROT SET
ALARMS
ENTER
ENTER
ENTER
PROT SET
ALARMS
PROT SET
ALARMS
ENTER
ENTER
ENTER
Summary of Contents for XDC
Page 2: ......
Page 3: ...Operating Manual for XDC 6000 Watt and 12000 Watt Series Digital Programmable DC Power Supply ...
Page 22: ...List of Figures xx Operating Manual for XDC Series Power Supply ...
Page 180: ...Current Sharing 6000 Watt only Operation 178 Operating Manual for XDC Series Power Supply ...
Page 216: ...SCPI Command Reference Expressions 214 Operating Manual for XDC Series Power Supply ...
Page 228: ...GPIB Performance Specifications 226 Operating Manual for XDC Series Power Supply ...
Page 253: ......