Operation
Power Supply Operation
72
Operating Manual for XDC Series Power Supply
To set both OTP and AC Off to Auto-Recovery:
Respond to
Alarms
If there is a protection alarm, press the
PROT SET/ALARMS
key to read the
message or messages. Once you have read a message, the system clears it from
memory. To tell the system that a message has been read, press an arrow key. If a
message has been read and the conditions that caused the alarm no longer exist, the
display shows
Alarms Cleared
.
If the unit has shut down, resume operation by pressing the
OUT ON/OFF
key.
The following table shows what to do if there is an OC Alarm and an OP Alarm, and
the conditions that caused the alarms no longer exist:
Step # Do This
You Will See
1
ERROR MSGS
2
3 times
1
1. You can also press
MENU
4 times to bring up the Shutdown Recovery option.
S/D RECOVERY
3
OTP Latched
2
2. The default is
Latched
. You can leave it at Latched or change it to Auto-Recovery. Press
either arrow key repeatedly until the desired option appears.
4
OTP AutoRecov
5
ACO AutoRecov
3
OTP is set to Auto Recovery.
3. The default is
AutoRecov
. You can leave it at Auto-Recovery or change it to Latched. Press
either arrow key repeatedly until the desired option appears.
6
ACO remains set to Auto Recovery
and the display returns to its default
operating mode.
MENU
ENTER
ENTER
ENTER
Step # Do This
You Will See
1
OC Alarm
2
OP Alarm
PROT SET
ALARMS
Summary of Contents for XDC
Page 2: ......
Page 3: ...Operating Manual for XDC 6000 Watt and 12000 Watt Series Digital Programmable DC Power Supply ...
Page 22: ...List of Figures xx Operating Manual for XDC Series Power Supply ...
Page 180: ...Current Sharing 6000 Watt only Operation 178 Operating Manual for XDC Series Power Supply ...
Page 216: ...SCPI Command Reference Expressions 214 Operating Manual for XDC Series Power Supply ...
Page 228: ...GPIB Performance Specifications 226 Operating Manual for XDC Series Power Supply ...
Page 253: ......