XDL 56-4 & XDL 56-4P
Step/Range Settings
Adjust
for:-
Load
Detail
1, 56V 2A
0.01V 2A
10mV ± 0.5mV
DVM
o/p 0V
2, 56V 2A
0.01V 2A
0.010V on display
DVM
V readback zero
3, 56V 2A
35V 2A
35V ± 0.5mV
DVM
o/p V span
4, 56V 2A
35V 2A
35.000 on display
DVM
V readback span
5, 56V 2A
41V 2A
41.000 on display
DVM
V readback 13bit
6, 56V 2A
0.01V 2A
10mV ± 0.5mV
DVM
o/p 0V
7, 56V 2A
35V 2A
35V ± 0.5mV
DVM
o/p V span
8, 56V 2A
2V 0.001A
1mA ± 0.5mA
milli-ammeter
o/p A offset
9, 56V 2A
2V 0.001A
0.001 on display
milli-ammeter
A readback zero
10, 56V 500mA
2V 0.1mA
0.1mA ± 0.05mA
milli-ammeter
o/p mA offset
11, 56V 500mA
2V 0.1mA
flashing 0.0/0.1 on display
milli-ammeter
mA readback zero
change
load
12, 25V 4A
2V 4A
4A ± 0.5mA
ammeter
o/p A span
13, 25V 4A
2V 4A
4.000 on display
ammeter
A readback span
14, 56V 500mA
2V 400mA
400mA ± 0.05mA
ammeter
o/p mA span
15, 56V 500mA
2V 400mA
400.0 on display
ammeter
mA readback span
16, 56V 500mA
2V 410mA
410.0 on display
ammeter
mA readback 13bit