Features and Specifications
Features and Options
12
Operating Manual for XKW 1kW Series Power Supply
Features and Options
•
Simultaneous digital display of both voltage and current.
•
Ten-turn front panel voltage and current controls for high resolution setting of
the output voltage and current from zero to the rated output.
•
Automatic mode crossover into current or voltage mode.
•
115/230 Vac selectable input voltage, 47–63 Hz single phase.
•
High frequency switching technology allows high power density, providing
increased power output in a small, light package.
•
Multiple units can be connected in parallel or in series to provide increased
current or voltage and operated in master/slave mode.
•
Remote sensing to compensate for losses in power leads up to 1 V per lead
(0.5 V for 8 V model).
•
Adjustable Over Temperature Protection (OTP).
•
External TTL, AC, or DC shutdown.
•
Remote voltage, current limit and over voltage protection (OVP) programming
with selectable programming ranges.
•
External indicator signals for remote monitoring of OVP status, local/remote
programming status, thermal shutdown and output voltage and current.
•
Isolated analog remote programming control of the output voltage or current
with the optional ISOL Interface.
•
Optional internal GPIB control for remote digital programming and readback
from a computer.
Front Panel Controls
See
Figure 1.1
to review the controls, LEDs, and meters located on the power
supply’s front panel. Check the following sections for additional descriptions of front
panel controls and functions.
•
“Mechanical Specifications” on page 21
•
“Functional Tests” on page 30
•
Section 3, “Operation”