Features and Specifications
Specifications
Release 2.2
19
Additional
Specifications
Input
Conditions
Additional
Features
Rise Time (No Load, Full Load):
1
300 ms (full load and no load)
Fall Time (No Load):
1
5 s
Fall Time (Full Load):
1
200 ms
Voltage Mode Transient Response:
2
1 ms
Time Delay from power on until
output stable
2 s maximum
1. Measured with stepped 0-10 V analog programming source and a resistive load.
2. Time for the output voltage to recover within 1% band for 30% step load change from
70% to 100% or 100% to 70%.
Rated AC Input Voltage with
Maximum Input Current
200-250 Vac at 10 Arms or 100-130 Vac at
20 Arms
Maximum AC Input Power
1300 W at full load
Operational AC Input Voltage
200-250 Vac or 100-130 Vac
Input Frequency Range
47-63 Hz
Power Factor
approx. 0.7 at full load
Switching Frequency
Nominal 100 kHz, 200 kHz output ripple
>80 V models: 80 kHz, 160 kHz output ripple
Output Hold-up Time
15 ms at full load, nominal line
Maximum Voltage Differential from
either output to safety ground
±600 Vdc
Insulation Resistance
Input to chassis: >30 M
Ω
, with 500 Vdc;
1
Output to chassis: >20 M
Ω
, with 1000 Vdc.
Isolation Voltage
Input to output: 1350 Vac
1. To protect from power surges, the units have a 420 Vac varistor built in to act as an
over-voltage clamp. The above insulation resistance specification is subject to be
measured with the varistors taken out of the circuit