Section 1. Features and Specifications
Electrical Specifications
18
Operating Manual for XPD Series Power Supply
Electrical Specifications
These specifications are warranted over a temperature range of 0 °C to 50 °C
with local sense. Above 50 °C, derate output linearly to zero at 70 °C. Nominal
line voltages are 100/120/200/230/240 Vac. Specifications and characteristics
refer to a single output model unless otherwise stated, and specifications apply
to either front or rear outputs unless noted.
Table 1.3
Electrical Specifications for 7.5 V to 120 V Models
Models
7.5-67
18-30
33-16
60-9
120-4.5
Output Ratings:
Output Voltage
Output Current
Output Power
0-7.5 V
0-67 A
1
502.5 W
0-18 V
0-30 A
540 W
0-33 V
0-16 A
528 W
0-60 V
0-9 A
540 W
0-120 V
0-4.5 A
540 W
Line regulation:
2
Voltage (0.01% of Vmax + 2 mV)
Current (0.01% of Imax + 1 mA)
2.8 mV
7.7 mV
3.8 mV
4 mV
5.3 mV
2.6 mV
8 mV
1.9 mV
14 mV
1.5 mV
Load Regulation:
3
Voltage (0.01% of Vmax + 2 mV)
Current (0.01% of Imax + 5 mA)
2.8 mV
11.7 mA
3.8 mV
8 mA
5.3 mV
6.6 mA
8 mV
5.9 mA
14 mV
5.5 mA
Meter Accuracy
Voltage (1% of Vmax + 1 count)
Current (1% of Imax + 1 count)
0.2 V
0.8 A
0.3 V
0.4 A
0.5 V
0.3 A
0.7 V
0.2 A
2.2 V
0.2 A
Output Noise (0-20 MHz):
Voltage (p-p)
50 mV
50 mV
75 mV
125 mV
180 mV
Output Ripple (0-100 kHz) (rms):
Voltage
Current
4
5 mV
250 mA
5 mV
250 mA
7.5 mV
150 mA
10 mV
150 mA
20 mV
75 mA
Drift (60 minutes):
5
Voltage (0.15% of Vmax)
Current (0.3% of Imax)
11.3 mV
201 mA
27 mV
90 mA
49.5 mV
48 mA
90 mV
27 mA
180 mV
13.5 mA
Drift (8 hours):
6
Voltage (0.03% of Vmax)
Current (0.05% of Imax)
2.3 mV
34 mA
5.4 mV
15 mA
9.9 mV
8 mA
18 mV
4.5 mA
36 mV
2.3 mA
Temperature Coefficient:
7
Voltage (0.015% of Vmax/º C
Current (0.02% of Imax/º C
1.2 mV
13.4 mA
2.7 mV
6 mA
5 mV
3.2 mA
9 mV
1.8 mA
18 mV
0.9 mA
OVP Adjustment Range:
Minimum (5% of Vmax)
Maximum (110% of Vmax)
0.4 V
8.3 V
0.9 V
19.8 V
1.7 V
36.3 V
3 V
66 V
6 V
132 V
Efficiency
8
81%
83%
85%
85%
84%
Summary of Contents for XPD 120-4.5
Page 2: ......
Page 3: ...Operating Manual for XPD Series Programmable DC Power Supply...
Page 50: ...Section 3 Local Operation User Diagnostics 48 Operating Manual for XPD Series Power Supply...
Page 54: ...Section 4 Remote Operation Status Flags 52 Operating Manual for XPD Series Power Supply...
Page 55: ......