Configuration
3–6
975-0400-01-01
Table 3-2
Battery Menu Values
Setting
Values
Default
Description
Equalize
Activate
Activate/Stop
Activate
Enables or disables Battery
Equalization. If the Battery Type
is set to GEL or AGM, this
setting is disabled.
Equalization
Reminder 0d
0–365 d(ays)
0 d
Sets a reminder that notifies you
when the battery needs
equalizing. If set to 0, the
reminder is disabled.
Battery
Bank 1
1–12
1
Selects the battery bank
connected to the XW SCC. This
is important for networked
installations, where multiple
devices must coordinate their
activity around common DC
connections.
Battery Voltage
12V
Auto, 12V, 24V,
36V, 48V, 60V
n/a
Selects your battery voltage. The
XW SCC automatically detects
12V, 24V, and 48V systems at
startup. Select the nominal
voltage level that matches your
system’s battery voltage.
Battery Type
Flooded
Flooded, GEL,
AGM, Custom
Flooded
Selects your battery type.
Selecting Custom allows you to
adjust the Equalize, Bulk,
Absorption, and Float Voltage
settings. Battery temperature
compensation can also be
adjusted on the Custom Battery
menu. The Custom option is
available only when advanced
menus are displayed.
Custom Battery
Menu
n/a
n/a
Press Enter to display the
Custom Battery menu and
configure a custom battery type.
See “Setting a Custom Battery
Type” on page 3–8.
Capacity 440Ah
Limit
60.0A
50–2000Ah
6.0–60.0A
440Ah
60.0A
Line 1:
Sets the amp-hour
capacity of your battery bank.
Line 2:
Sets the charging current
limit.
ReCharge Volts
12.5V
12V: 10.0–13.5V
24V: 20.0–27.0V
36V: 30.0–40.5V
48V: 40.0–54.0V
60V: 50.0–67.5V
12.5V
25.0V
37.5V
50.0V
62.5V
Sets the voltage at which the
charger transitions from Float or
No Float back to Bulk, or from
Absorption back to Bulk.
Summary of Contents for XW-MPPT60-150