Configuration
3–8
975-0400-01-01
Setting a Custom Battery Type
The Custom Battery menu allows you to adjust charging and equalization voltage
for batteries whose specifications fall outside of the default settings for the battery
types the XW SCC offers.
You can also adjust the temperature compensation constant for the Battery
Temperature Sensor on the Custom Battery menu.
The following table describes the options available on the Custom Battery menu.
CAUTION: Equipment damage
To avoid damaging your batteries during charging or equalization, consult your battery
manufacturer and associated documentation before setting a custom battery type.
Important:
•
Setting the Battery Type to Custom is possible only when advanced menus are
displayed.
•
The Custom Battery menu is displayed only when the Battery Type is set to Custom.
•
All settings for configuring a Custom battery type are based on the default settings for
a Flooded battery type.
Table 3-3
Custom Battery Menu Values
Setting
Values
Default
Description
Equalize Support
ON
ON, OFF
ON
Selects whether Equalization
will be allowed or not for the
Custom battery type.
Equalize Voltage
16.0V
12V: 13.5–16.0V
24V: 27.0–32.0V
36V: 40.5–48.0V
48V: 54.0–64.0V
60V: 67.5–72.0V
16.0V
32.0V
48.0V
64.0V
72.0V
Selects the equalization
voltage (consult your battery
manufacturer for equalization
voltage setting).
This screen is hidden if
Equalize Support is OFF.
Bulk Voltage
14.4V
12V: 10.0–16.0V
24V: 20.0–32.0V
36V: 30.0–48.0V
48V: 40.0–64.0V
60V: 50.0–72.0V
14.4V
28.8V
43.2V
57.6V
72.0V
Sets the bulk voltage for a
custom battery type.
Absorb Voltage
14.4V
12V: 10.0–16.0V
24V: 20.0–32.0V
36V: 30.0–48.0V
48V: 40.0–64.0V
60V: 50.0–72.0V
14.4V
28.8V
43.2V
57.6V
72.0V
Sets the absorption voltage
for a custom battery type.
Summary of Contents for XW-MPPT60-150
Page 1: ...XW Solar Charge Controller Owner s Manual XW MPPT60 150 ...
Page 2: ......
Page 3: ...XW Solar Charge Controller Owner s Guide ...
Page 12: ...x ...
Page 86: ...5 4 ...
Page 102: ...B 12 ...
Page 109: ......