Charging of the Pb battery
Charging of the Pb battery
Battery
type
DEC
Pb CHARGE
4.0A 12.0V(6P)
Pb-6 4.0A 12.59V
CHG 022:43 00682
-
Batt type
Stop
Elapsed
time
INC
+
Charge
current
Battery
voltage
DEC
Start
Enter
-
INC
+
Charged
capacity
Set up the charge current on the left and nominal voltage on the right.
Range of current is 0.1-5.0A, the voltage should match the battery being
charged. Press 'START/ENTER' key for more than three seconds to
begin charging.
This screen displays the real-time charging status. Press the
'
START/ENTER' key to change the discharge current. Press
'START/ENTER' key again to store the parameter value you set. Press
the 'BATT TYPE/STOP' key to end the program.
Discharging of t he Pb batteryy
DEC
Pb DISCHARGE
1.0A 12.0V(6P)
-
Batt type
Stop
INC
+
DEC
Start
Enter
-
INC
+
Set up the charge current on the left and nominal voltage on the right.
Range of discharge current is 0.1-5.0A, the voltage should match the
battery being charged. Press the 'START/ENTER' key for more than
three seconds to begin charging.
Pb-6 0.4A 12.59V
DSC 022:43 00682
This screen displays the real-time discharging status. Press the
'
S TA R T / E N T E R ' k e y t o a l t e r d i s c h a r g e c u r r e n t . P r e s s t h e
'START/ENTER' key again to store the parameter value you set. Press
the 'BATT TYPE/STOP' key to end the program.
Battery
type
Elapsed
time Discharge
current
Battery
voltageDischarged
capacity
24
’
>
3 seconds’
’
>