XceedID : Document No: 0469-01; Issue No. 1; 4/12/2007
2. Use a DC power source between 5 volts and 16 volts.
3. Be sure the reader is properly grounded by attaching the ground wire to an earth ground
connection at the power supply or panel end of the cable.
Testing the Reader:
1. Power up the reader. The LED will light followed by a beeper tone. This indicates that
the reader is ready.
2. Present a proper card or token programmed to operate the reader and a green LED
flash will indicate successful operation. Note that a red flash could simply indicate an
incorrect match or miss-programmed card/token rather than a faulty reader installation.
Additional Notes:
•
The voltage specification for these products is 5 volts to 16 volts.
•
Typical cable gauge ranges from 18 to 22 gauge. Check with your cable supplier to
determine the best choice for your application and installation distance
.
Specifications:
•
Power Supply: DC
•
Voltage Range: 5 – 16VDC
•
Temperature Range: -35C to +65C (-31F to 149F)
•
Card Read Distance: Up to 4.5” (115 mm) – Distance can vary widely depending on
installation conditions and credential type.
•
Cable Distance to Panel in Wiegand mode:
o
500 ft. maximum @ 22 awg for 12 volt supply.
o
200 ft. maximum @ 22 awg for 5 volt supply.
•
Information Output: Wiegand
•
Regulatory Approvals and Standards
UL 294
ISO15693
ISO14443A
Europe: CE Listed.
Federal Communications Statement:
The FCC requires the following statement for your information:
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation.
This reader utilizes and radio frequency energy and has been tested and complies with the limits
of FCC testing. Changes, modifications or disregard of proper installation instructions not
expressly approved by XceedID Corporation is strictly prohibited by the FCC and could void the
user’s authority to operate the equipment.
For Canadian Users:
This unit has been tested and meets all applicable Industry of Canada technical specifications.
•
This device may not cause radio frequency interference.
•
This device must accept radio frequency interference.
In the unlikely event interference occurs, please contact the manufacturer.