9. Troubleshooting

Warning! Before machines are dispatched from the factory, they have already

been checked thoroughly. The machine should not be tampered with or altered.

Maintenance must be carried out carefully. If any wire becomes loose or is

misplaced, it maybe potentially dangerous to user! Only professional

maintenance personnel should repair the machine!

Ensure the power is disconnected before working on the machine. Always wait

5 minutes after power switch off before removing the panels.

9.1. Common malfunction analysis and solution

The symptoms listed here may be related to the accessories, gas,

environmental factors, and power supply you use. Please try to improve the

environment and avoid such situations.

Symptom

Reasons

Troubleshooting

No pilot arc after

pressing the torch

trigger

·The machine is in gas check

mode

·The torch trigger circuit is

blocked

·Compressed air is not

connected

·The pilot arc circuit is damaged

·Turn off the gas check function or

wait 20s to exit automatically

·Check the torch trigger circuit

·Reconnect the compressed air

·Replace or repair the mainboard

The pilot arc is

discontinuous or

extinguishes

·The consumables are seriously

worn

·Input compressed air pressure

is too high

·Too much moisture or

impurities in the compressed air

·Pilot arc time exceeds 2s

·Replace with new consumables

·Adjust the pressure of compressed

air to 0.35-0.55MPa through the gas

regulator on the rear panel

·Manually drain the water in the filter

cup of the gas regulator on the rear

panel or replace the valve

·Don’t press the torch to keep pilot

arc for a long time without cutting.

The pilot arc cannot

be transferred to the

workpiece

·The cutting circuit is blocked

·Too much distance between

the tip of cutting torch and the

workpiece

·Check whether the earth clamp is

damaged and clean the part which

contacts the workpiece, and ensure

good metal-to-metal contact

·Ensure that the distance between

the tip of the cutting torch and the

workpiece remains within 3-5mm

Troubleshooting

Common malfunction analysis and solution

Summary of Contents for RAZOR CUT 45 PFC

Page 1: ...YEAR MACHINE WARRANTY 3 3 XA RZCUT45PFC K Operating Manual...

Page 2: ...he future RAZORCUT Plasma Cutters are manufactured and compliant with CAN CSA E60974 1 ANSI IEC 60974 1 AS NZ60974 1 guaranteeing you electrical safety and performance Air quality Good air quality is...

Page 3: ...escriptions 9 Power Installation 10 Set Up and Operating Procedure 11 Control panel 12 14 Plasma Cutting Procedure Techniques 15 18 SC40 Plasma Torch Parts Breakdown 19 Trouble Shooting 20 REGISTER YO...

Page 4: ...r cable for wear and tear replace the cable immediately if damaged bare wiring is dangerous and can kill Do not use damaged under sized or badly joined cables Do not drape cables over your body We rec...

Page 5: ...r can explode Because gas cylinders are normally part of the welding cutting process be sure to treat them carefully CYLINDERS can explode if damaged Protect gas cylinders from excessive heat mechanic...

Page 6: ...er table This equipment is of automatic voltage compensation which enables the maintaining of the voltage range within the given range In case that the voltage of input power supply amperage exceeds t...

Page 7: ...aterial such as hafnium and cerium This insert erodes with use also the nozzle orifice will erode with use Quality of the air used is paramount to longer life of electrodes and nozzles in short clean...

Page 8: ...asy to operate With its exceptional performance reliability and ease of use the RAZOR CUT45 is an excellent investment for anyone in need of a high quality plasma cutting machine Whether you re a prof...

Page 9: ...may damage the equipment Warning This product meets the requirements of Class A equipment in EMC requirements and is not to be connected to a residential low voltage power supply grid 5 1 External int...

Page 10: ...larger cross sectional area to reduce the voltage drop 3x2 5mm2 or more is recommended Page 13 5 2 Power installation Warning The electrical connection of equipment shall be carried out by suitably q...

Page 11: ...tage drop due to the cable length Compressed air Page 13 5 2 Power installation Warning The electrical connection of equipment shall be carried out by suitably qualified personnel Warning All connecti...

Page 12: ...nd indicators 6 2 Display of parameters and error codes 1 Electric current configuration 2 When the factory settings are restored the countdown is displayed 3 In user mode the parameter settings are d...

Page 13: ...Press the gas check button while not in cutting state 2 When the indicator is lit the machine is in gas check mode 3 Press the gas check button again or wait 20s After the indicator light goes out ma...

Page 14: ...that time to exit the countdown without entering engineer mode 3 Engineer mode F01 Standby time selection 0 5 10 or 15 unit is min 0 means that the standby function is not enabled F02 Input over volt...

Page 15: ...e job or bench is wet and you place your hand or arm on it you can become part of the circuit and receive a shock be sure you are wearing leather gloves Full length pants and covered shoes Wear eye pr...

Page 16: ...d the extent of the bevel of the cut The easiest way to reduce bevel is by cutting at the proper speed and height for the material and amperage that is being cut Correct torch height and square to the...

Page 17: ...ir supply is absolutely critical to quality plasma cuts and longevity of consumable parts As a minimum be sure to drain the receiver tank on the air compressor at least daily Most air plasma systems f...

Page 18: ...then push the electrode up and down for 10 20 times Remove the excess grease before assembling the torch Torch Head Electrode Holder Lubrication Apply in case of sticking or start stop is delayed Appy...

Page 19: ...Tip 0 9mm Cross Groove 12 SC8026 10 Contact Cutting Tip 1 0 mm 40 50A SC8026 11 Contact Cutting Tip 1 1 mm 50 60A SC8026 12 Contact Cutting Tip 1 2 mm 60 70A SC8026 13 Contact Cutting Tip 1 3 mm 70 80...

Page 20: ...uit is damaged Turn off the gas check function or wait 20s to exit automatically Check the torch trigger circuit Reconnect the compressed air Replace or repair the mainboard The pilot arc is discontin...

Page 21: ...epartment E32 Overvoltage protection Input grid voltage is too high Turn it off and on again If the alarm cannot be eliminated and the grid voltage remains too high check the power grid voltage and wa...

Page 22: ...imes of the machine so as to lengthen service life of the machines Period Maintenance item Daily examination Check the condition of the machine mains cables welding or cutting cables and connections C...

Page 23: ...23 Notes...

Page 24: ...24 Esseti New Zealand Limited PO Box 4189 Palmerston North 4442 Phone 06 355 1103 Fax 06 354 2437 Email sales esseti co nz www esseti co nz Xcel Arc Esseti NZ LTD 2023 New Zealand Limited...

Reviews: