HUMIDIFY AND HUMIDITY SETPOINT
21
>>
HUMIDIFY SETPOINT
: Allows you to increase and maintain the relative humidity at
a specific setpoint. Once you choose
HUMIDIFY
follow these easy steps:
• The
HUM
setpoint with
-
and
+
icons allow you to lower and raise your setpoint.
*
Example of the typical use of the Humidify Function: If the current humidity is 30%
your TrueTouch™ thermostat will initiate the humidifier to function until Setpoint
50% is reached. In order to humidify you must set the humidity setpoint above the
current humidity.
AUTOMATIC HUMIDITY CONTROL
20
>>
In order to reduce condensation, humidity must be controlled and air move-
ment must be generated. As the exterior temperature drops, the humidity
level needs to decrease if condensation is to be controlled.
HUMIDITY AUTO
: TrueTouch™ thermostat will automatical-
ly adjusts the humidity set point based on the current indoor
temperature and humidity as well as the current outdoor tem-
perature in order to maintain a maximum comfort level and
eliminate condensation. The automatic humidity setpoint is
determined according to the following standard humidity table.
1
Setpoint
Outdoor Temp in °C
Outdoor Temp in °F
15%
-29
-20
20%
-24
-10
25%
-18
0
30%
-12
10
35%
-7
20
40%
-7
-20
HUMIDITY MANUAL
: The user selects the humidity setpoint.
1