XE210C Hydraulic Excavator
Operating and Maintenance Manual
144
Storage and protection
Daily and short-term storage and protection
Check the machine, repair the worn and damaged parts. If necessary, attach new parts.
Clean the air filter element.
If possible, retract all the hydraulic cylinders; if impossible, apply the grease to the exposed rod of
hydraulic cylinder.
Lubricate all the lubrication points.
Place the crawler on the long and stable damp block.
Clean the machine.
After charging the battery up, remove the battery and store it at dry and safe place. If not, separate the
connection of battery negative-pole cable on the wiring terminal (-).
Add the anti-rust agent into engine coolant. In winter, adopt the anti-freezing agent or drain the
coolant off. If the cooling system is emptied, be sure to hang a nameplate “No Water of Radiator” in
conspicuous position
.
Loosen the belts of AC generator and cooling fan.
Apply the paint to desired positions to avoid rusting.
Store the machine at dry and safe place. In case of storing it outdoor, adopt the water shield.
Long-term storage
Storage place
a)
Commonly store in the ventilated and dry warehouse.
b)
If the device is stored in open air, park it on the concrete ground easy to drain the water, cover and fix
the canvas or hood, and store it at the place that can’t be invaded by natural disaster and without
corrosive or harmful substance or gas.
Storage
a)
Use the hydraulic functions of moving, rotation and digging twice to three times every month to
lubricate all the parts. Check the level of coolant and lubrication state before the operation.
b)
Check the appearance quality, protection side and anti-corrosion substances, etc at regular intervals.
Use preparation after storage
Remove the coverings.
Remove the protective substances painted on the exposed part.
Charge the battery, mount or connect it.
After draining the oil of engine crankcase, renew the oil.
After draining the gear oil in the rotary and traction reducer, renew the gear oil.
Drain the inclusions and mixed water out of the hydraulic oil tank and fuel tank.
Apply the grease to each hinged position.
Fill in the coolant as per the specification.
For the check before the operation, refer to the relevant regulations of operation.