Manual of XZ320 Horizontal Directional Drill
42
Figure 15 for clamping.
Figure 15 Clamping diagram of auger stem
8.1 Stop the power head and hold the auger stem when connector is
between front and post jaw vices.
Press clamping switch of front jaw vice (2) until auger stem is clamped with
certain pressure.
Press clamping switch of post jaw vice (1) until auger stem is clamped with
certain pressure.
8.2 Cut off the front connector.
Press rotation switch of post jaw vice (1) and rotate the post jaw vice
counter-clockwise then cut off the connector.
Open the post jaw vice then rotate it clockwise so that it can return to its
original position.
8.3 Separate the front connector.
8.3.1 Clamp the auger stem by post jaw vice
;
8.3.2 Rotate the power head counter-clockwise and loosen the connecting
thread
;
8.3.3 Rotate auxiliary loading/unloading device of auger stem and clamp
the auger stem so that post jaw vice can loosen the auger stem;
8.3.4 Rotate the main axle slowly and counter-clockwise, move power
head backward, detach the auger stem then rotate auxiliary
loading/unloading device of auger stem and detach the augers tem. (Pay
attention to relative position of auger stem and jaw vice to avoid collision of
rotary auger stem and jaw vice or bonding with connecting thread of drill
collar.)
8.4 Connect it to the next auger stem.
8.4.1 Move the power head forward until main axle pin contacts auger
top-stm.ru