background image

 

 

-

 

Avoid contact with cables terminals when modules are exposed to light. 

-

 

Do not attempt to install or use a module with broken front cover glass or a 
perforated backsheet. 

 

-

 

Keep solar module(s) in original packing until point of assembly/installation to 
reduce risk of damage. 

-

 

Cover module face(s) completely with opaque material to halt the production 
of electricity when working with module wiring. Disconnect module(s) from 
other sources of electricity, such as batteries, when working on system. 

-

 

Avoid artificial or concentrated sunlight directed on module 

-

 

Avoid shadowing cells in order to prevent solar module hot spots and/or 
reduction in power. 

 

-

 

Newer touch the terminals with bare hands. 

-

 

Use insulated tools when wiring to solar module terminals, wear rubber gloves 
to eliminate shock or burn potential when wiring solar modules. 

 

 

Regardless of whether you are working on a new or existing roof, never allow 
the sheathing and metal parts to become wet.  

 

Protect the sheathing and metal parts from rain during the installation. Failure 
to do so may cause leaks. 

 

Work under dry conditions with dry tools. 

 

Avoid installing modules and mounting system in high corrosion areas. 

 

 

Do not install near flammable gases. 

 

APPLICATION 

ASOL-250P-WSR modules are designed to provide high-power output for roof mounted/building integrated 
photovoltaic  systems  as  well  as  in-grid  systems.  The  modules  are  assigned  to  the  Application  class  A  (in 
accordance with IEC 61730). The modules thus fulfil the requirements of Protection class II. 

Summary of Contents for ASOL-250P-WSR

Page 1: ...MOUNTING INSTRUCTION for PHOTOVOLTAIC MODULES Type ASOL 250P WSR ...

Page 2: ...UNDING 6 ELECTRICAL SPECIFICATIONS 6 By pass diode specifications 6 LOCATION SELECTION 6 MODULE TILT ANGLE 6 MOUNTING OF THE MODULES 7 Clips location 7 Mounting with screws 9 MAINTENANCE OF PHOTOVOLTAIC MODULES ASOL 250P WSR 9 Periodic cleaning of the module 9 Visual inspection 9 Connection and wiring controls 10 Manufacturer 10 ...

Page 3: ...d professional manner Electrical work should be performed by a qualified electrician WARNING This photovoltaic module produces electricity when exposed to the sun or other light sources The electrical hazard from the voltage and current of a single module is low However the voltage increases as modules are connected in series and the available current increases as modules are connected in parallel...

Page 4: ...uch the terminals with bare hands Use insulated tools when wiring to solar module terminals wear rubber gloves to eliminate shock or burn potential when wiring solar modules Regardless of whether you are working on a new or existing roof never allow the sheathing and metal parts to become wet Protect the sheathing and metal parts from rain during the installation Failure to do so may cause leaks W...

Page 5: ...for components capacity of conductors size of fuses and size of control systems connected to the module output are determined multiply the values of short circuit current Isc and open circuit voltage Voc that are marked in ASOL 250P WSR series modules by the coefficient 1 25 Before installing your system contact local authorities to determine the necessary permit installation and inspection requir...

Page 6: ...st Conditions rated power Accordingly when determining component ratings and capacities the module short circuit current at STC should be multiplied by 1 25 and a correction factor should be applied for the open circuit voltage An additional 1 25 multiplier for the short circuit current for a total of 1 56 for sizing conductors and fuses may be applicable depending on your local regulations BY PAS...

Page 7: ... location RECOMENDED TILT ANGLES FOR A FIXED SYSTEM SITE LATITUDE IN DEGREES FIXED TILT ANGLE 0 to 15 15 15 to 25 SAME AS LATITUDE 25 to 30 LATITUDE 5 30 to 35 LATITUDE 10 35 to 40 LATITUDE 15 40 LATITUDE 20 MOUNTING OF THE MODULES CLIPS LOCATION XDISC S A recommends using typical aluminium clips designed for framed modules ASOL 250P WSR module mounting configurations must meet the following requi...

Page 8: ...e mounted and must not cause any twist or stress to be placed on the module Modules should be secured to mounting structure using four aluminium at least 80 mm long module clips The retaining clips must each provide a minimum contact area of 10 mm x 80 mm The centre of mounting clips must be located on the long side of the module between 350 mm and 400 mm from the edge See following figure for all...

Page 9: ...d on the transparent cover of the module reduces its performance and can produce reverse effects similar to those produced by shading The problem can become serious in the case of industrial waste or waste caused by birds The intensity of the effects depends on the opaqueness of the residue The layers of dust that reduce the intensity of the sun are not dangerous and the reduction in power is not ...

Page 10: ... wiring Also check to be sure that mounting hardware is tight Loose connections will result in damage for array Do not touch live parts of cables and connectors Use appropriate safety equipment insulated tools insulating gloves etc when touching them Cover the front surface of the Module by an opaque or other material when repairing The ASOL 250P WSR modules when exposed to sunlight generate high ...

Reviews: