- 9 -
(1) How to mount brush
4. How to mount and replace brush
1) As shown in Fig.13 use a hexagonal wrench to adjust the amount of projection for starting
setting.
2) While inserting the brush into the brush holder, fasten brush fixed screws (M2.6 × 2 pcs.)
by mutually tightening both sides evenly without fail to prevent the deviation (prevent
run-out), then tighten the screws with the torque 0.7N·m by using torque wrenches at the
end.
At this time, please ensure that there is no gap between the brush bottom surface and
brush holder inner surface to prevent run-out of the brush. (Fig. 14)
(1) How to mount brush
(XP-AUT15M)
(XP-AUT06M)
1) Align the brush screw holes with the brush holder screw holes. Match the screw holes by
rotating the brush holder if the brush holderʼs screw holes are deviated. (Fig. 18)
2) While inserting the brush into the brush holder, fasten brush fixed screws (M3 × 2 pcs.) by
mutually tightening both sides evenly without fail to prevent the deviation (prevent
run-out), then tighten the screws with the torque 1.6N·m by using torque wrenches at the
end. (Fig. 19)
At this time, please ensure that there are no gap between the brush bottom surface and
brush holder inner surface to prevent the brush run-out. (Fig. 20)
(2) How to replace brush
1) Remove the brush mounting screws at two locations. (Fig. 15)
2) Remove the brush from the brush holder. (Fig. 16)
3) As shown in Fig.17, pull in the brush fixing part and set at a desired position.
4) For reassembly, please refer back to (XP-AUT06M) (1) How to mount brush.
*Once brush is mounted on XP-AUT06, projection cannot be adjusted by a hexagonal wrench .
Please remove the brush and adjust as shown in Fig.13
Pull in the brush holder
Pull in the brush holder
Fig.13
Fig.14
Fig.15
Fig.16
Fig.17
Push the brush on the inner surface of the brush holder.
Brush mounting hole
Please rotate
Please ensure that no gaps are generated.
〇
×
Project the brush
Pull in the brush
Fig.18
Fig.19
Fig.20
Fig.22
Fig.23
Fig.24
(2) How to adjust brush projection amount
(3) How to replace brush
Insert a hexagonal wrench into the hexagonal wrench notch
at the tip of the rod to adjust the amount of projection. (Fig. 21)
Fig.21
1) Remove the brush mounting screws at two locations. (Fig. 22)
2) Remove the brush from the brush holder. (Fig. 23)
3) Pass a brush mounting screw through one of the brush mounting screw holes of the brush
holder to prevent the brush from rotating, and rotate the screw rod with a hexagonal wrench to
fix the brush at a desired position while paying attention to the screw not to fall out. (Fig. 24)
4)For reassembly, please refer back to (XP-AUT15M) (1) How to mount brush.