- 10 -
Other
6. Remarks
Fig.25
5. How to clean sleeve main body
(XP-AUT06M)(XP-AUT15M)
(XP-AUT06M)
(XP-AUT15M)
Clean inside of the guide sleeve and outside of the brush holder. (Fig. 25)
Guide sleeve fixing bolts (4)
Cover plate
Cover plate
Screw rod
Screw rod
Brush holder
Brush holder
Guide sleeve
Guide sleeve
Apply grease
Apply grease
Apply grease
Apply grease
Location to insert a hexagonal wrench
(holder bottom)
Location to insert a hexagonal wrench
(holder bottom)
Guide sleeve fixing bolts (4)
1) Remove the guide sleeve by loosening four pieces of the guide sleeve fixing bolts
2) Remove the brush holder
3) Apply grease after cleaning/wiping outside of the screw rod/brush holder and inside of
the guide sleeve with parts cleaner.
*Our companyʼs recommended grease: lithium soap grease (NLGI No. 2)
4) Return the brush holder to the screw rod and tighten four pieces of M4 guide sleeve
fixing bolts at the torque 2.5N·m by using torque wrenches.
5) Please confirm in advance that there is no run-out before usage. Please confirm also
that there are no loose screws, etc. after machining for a while.
Apply grease to sleeve
inner diameter
Apply grease to sleeve
inner diameter
* When removing and re-assembling the guide sleeve please do so carefully as the clearance is
minimal and lack of care can result in binding and hence damage.
* If storing for any time without use please ensure to clean and grease the sliding fit so the unit
does not seize whilst not in use.
* Please inquire through your procurement source if any abnormalities are sensed in the
mechanism area.
* Please inquire regarding maintenance parts through your procurement source.
* This product is an optional tool for φ6 or φ15 XEBEC Brush™ Surface.
* Please fasten screws with specified tightening torques by using torque wrenches.
* Please use upon confirming that there are no loose screws before usage.
* Specifications and shapes of the product may change without prior notice.