This unit is a two stage, constant current 
battery charger for charging nickel-metal-
hydride type rechargeable batteries. The 
charge termination is by a 14 hours timer at 
which time it will switch from the charge 
current to a low rate current. A 6 feet long 
output cable with a barrel plug is provided. 
There are two indicators on the front panel. 
The orange light indicates that the charger is 
in the charging mode. The green light 
indicates that the battery is fully charged. 
 
 

ASSEMBLY INSTRUCTIONS 

 
Loosen the screws on the charger output terminal 
strip. Identify the polarity of the terminal strip ant 
the output connector; both the charger housing 
and the output cable are marked with “+” & “-” 
symbols. Insert the two spade terminals under the 
terminal strip screws and tighten. To prevent 
accidental shorting, cover the exposed terminals 
with the molded press-on terminal cover. 
 
If using loose wires, insert stripped ends under washers.  A cable having a shield may be 
grounded to the bottom hole using a number 6-32 x ¼” machine screw. 
 
 

OPERATING INSTRUCTIONS 

 
Before using this battery charger, make sure it is compatible with your battery. Refer to 
the ratings on the battery charger, the specifications in this manual, and your battery 
documentation. Charge only nickel-metal-hydride 
type rechargeable batteries; attempting to charge 
other types of batteries may result in battery damage. 
This unit is provided with a polarized barrel plug 
connector. Make sure your battery connector is 
wired to match the output connector. 
 

CAUTION:

   This unit is not reverse battery protected except by use of the polarized 

connector. Make sure your battery connector is wired to match the charger connector or 
damage to the battery and charger may result when power is applied. While in a reversed 
condition the charger will indicate that it is in the charging mode. However, it may 
actually be discharging the battery until either the battery or charger is damaged. 

Summary of Contents for MHTX7 Series

Page 1: ...User s Manual Rev 1 0 October 17 2006 For Sales Support and Service phone 407 331 4793 fax 407 331 4708 website www xenotronix com email information xenotronix com Xenotronix TLI Inc 2541 Tracy Road...

Page 2: ...is Warranty does not apply to and is rendered null and void by any Product which after leaving Seller s manufacturing plant a is repaired or altered without Seller s prior written approval b is the su...

Page 3: ...ery Charger User s Manual Important Safety Instructions 1 Introduction 2 Assembly Instructions 2 Operating Instructions 2 3 Charging Notes and Tips 3 4 Troubleshooting 4 5 Maintenance Instructions 5 B...

Page 4: ...ng off controls may not reduce this risk WARNING o Charge only nickel metal hydride type rechargeable batteries Attempting to charge other types of batteries may result in personal injury and battery...

Page 5: ...olded press on terminal cover If using loose wires insert stripped ends under washers A cable having a shield may be grounded to the bottom hole using a number 6 32 x machine screw OPERATING INSTRUCTI...

Page 6: ...arged When the charger is in the ready mode a low rate constant current 1 4 that of the rated output current is delivered to the battery to keep it fully charged Most nickel metal hydride batteries ma...

Page 7: ...oth dark when power is applied and the charger is properly attached to a battery check to see if the receptacle is controlled by a light switch or power strip It is normal for both indicators to be of...

Page 8: ...nect the battery before attempting any cleaning If it becomes necessary to clean the enclosure wipe the enclosure exterior with a damp cloth If necessary use a mild detergent Do not use an abrasive cl...

Page 9: ...MHTX7 User s Manual Xenotronix TLI 6 DIMENSIONS READY CAUTION CHARGING...

Reviews: